Voltage Range
Accuracy
N/A
0 to 400 mA
Power (Watts)
0 to 75 W
Electrical Requirements
100-120V, 50/60Hz, 100VA
5 V to 200 V; fully adjustable in 1 V steps
±1% at 200 V and 200 W
Current
0.01 A to 2.00 A; fully adjustable in 0.01 A steps
Current Accuracy
±10 mA
200 W
100-120V
10 V to 300 V; fully adjustable in 1 V steps
±1% at 300 V and 75 W
5 mA to 400 mA; fully adjustable in 1 mA steps
±1 mA
75 W
10 V to 300 V, fully adjustable in 1 V steps
+/- 2% of reading or 3 volts
4 mA to 400 mA, fully adjustable in 1 mA steps
+/- 2% of reading or 3 mA, whichever is more
5 V DC to 1000 V DC; fully adjustable in 1 V steps
±1% at 1000 V full scale
1 mA to 500 mA; fully adjustable in 1 mA steps
±1% at 500 mA full scale
1 W to 250 W; fully adjustable in 1 W steps
20 V DC to 3000 V DC; fully adjustable in 1 V steps
±1% at 3000 V full scale
1 mA to 400 mA; fully adjustable in 1 mA steps
±1% at 400 mA full scale
1 W to 400 W; fully adjustable in 1 W steps
5 V to 250 V, fully adjustable in 1 V steps
300 W
100–120/220–240 VAC, autoswitching
10 V to 500 V, fully adjustable in 1 V steps
500 W
Capacity
One 2-chamber disposable slide
Cell Size
6 to 50 µm
Concentration
5x10^4-1x10^7 cells/ml
Counting Time
30 seconds
Detection Method
Brightfield-based
Data Storage
100 Counts
Data Export
Via USB Drive
Sample Volume
10 µl
Dimensions (W x D x H)
7.5 x 6 x 10 in. (19 x 15 x 25.4 cm)
Weight
4.8 lb. (2.2 kg.)
120 - 240V, 30W
Thermal Range
0° to 99.9°C
±0.2°C
Thermal Uniformity
±0.4°C
Ramping Rate
2.5°C/sec
Sample Capacity
48 x 0.2ml tubes, 12 x 0.5ml tubes, or one 48 well microplate
Memory
400 typical programs in 12 folders
Gradient Function
Yes
100–240 VAC, 50-60 Hz, 400 W max
4° to 100°C
±0.5°C to NIST traceable standard after 30 seconds at 90°C, to block mode
Well to well uniformity of ±0.5°C within 30 seconds after arrival at 90°C
Heating: 2.5 °C/s
Cooling: 1.5°C/s
96-wells
99 programs on board
100-250 VAC, 50/60Hz
0° to 100°C
±0.2°C of programmed target at 90°C
±0.4°C
3°C/sec
Varies with installed Alpha unit
400 two step protocols
120-250 VAC, 50-60 Hz
5 to 105°C, but no more than 30°C below ambient temperature (4 to 100°C for the slide Chambers Alpha Unit)
± 0.3°C of programmed target at 90°C- NIST-traceable
± 0.4°C well-to-well within 30 seconds of arrival at 90°C (for most Alpha units; see specifications for individual Alpha Units)
Up to 3˚C
96-well plates
400 programs in 12 individual folders
100/120V, 50/60Hz
Dual 48-well plates
±0.2° of Programed target at 90°C
±0.4°C well to well within 10 sec of arrival at 90°C
3.3°C/sec
96 x 0.2 ml tubes
>1,000 Typical Programs
3.0°C/sec
2 x 48 x 0.2 ml tubes
100-240 VAC, 50/60Hz, 850W
Maximum sample size
28 x 36 cm
Maximum image area
25 x 26 cm
Excitation source
Trans UV 302, 254, 365 nm & White, Epi-White light
Illumination control
3 modes (trans-UV, trans white, epi-white)
Detector
CCD
CCD resolution (H x V)
768 x 494 RS-170 752 x 582 CCIR
Pixel size in microns (H x V)
8.4 x 9.8
Filter holder
2 positions (1 Emmision Filter, 1 Chemi)
Emission filters
1 included (amber), 4 optional
Dynamic range
1.8 Orders
Pixel density (gray levels)
8 bit (256 gray levels)
Dynamic flat fielding
No
19.4 x 26 cm
Pixel size (H x V)
4.65 x 4.65 µm
3 positions (2 for filters, 1 without filter)
1 included (standard), 3 optional
> 3.0 orders of magnitude
4,096
Application specific, for all applications
Applications
Chemiluminescence
Fluorescence
Yes Note: Use the optional XcitaBlue kit if performing SYBR® Safe DNA applications, because the UV to blue conversion screen allows you to visualize DNA samples while protecting against UV damage.
Instrument size (L x W x H)
36 x 61 x 96 cm
Instrument weight
32 kg
Operating temperature
10–28°C (21°C recommended)
Operating humidity
<70% noncondensing
36 x 60 x 96 cm
Instrument Size (L x W x H)
Instrument Weight
32 kg.
Operating Temperature
Operating Humidity