Home > Analyzers
Need help selecting a product? Use our new filter tool to help you find the right product.
Sort By:
Page of 1
Agilent 2100 Bioanalyzer G2938B with Chip Priming Station Agilent 2100 Bioanalyzer G2938B with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution
Degree 2

Our Price: $10,395.00
1 in stock!
Agilent 2100 Bioanalyzer G2939A with Chip Priming Station Agilent 2100 Bioanalyzer G2939A with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $10,495.00
3 in stock!
Agilent 2100 Bioanalyzer G2939B with Chip Priming Station Agilent 2100 Bioanalyzer G2939B with Chip Priming Station

Agilent 2100 Bioanalyzer G2939B with Chip Priming Station Specifications

Analysis Run Time 30 to 45 min
Number of Samples Up to 12 samples/chips
Sample Volume 1 µl
Sizing Range 25 to 7000 bp
Ambient Operating Temperature 5° to 40°C (41° to 104°F)
Safety Standards: IEC, CSA, UL Installation Category II, Pollution Degree 2
Power Consumption 30W / 60 VA
Dimensions (W x D x H) 162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)
Electrical Requirements 100-240VAC, 50-60Hz

Our Price: $11,995.00
1 in stock!
Agilent 2100 Bioanalyzer G2938C with Chip Priming Station Agilent 2100 Bioanalyzer G2938C with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $11,395.00
1 in stock!
Caliper Life Sciences LabChip XT Fractionation System Caliper Life Sciences LabChip XT Fractionation System

Caliper Life Sciences LabChip XT Fractionation System Specifications

Fluorescence Detection Wavelength

Bandpass 547 to 750 nm

Fluorescence Data Rates

80Hz

Light Source Warmup Time

30 seconds

Light Source Excitation/Emission Wavelengths

532 nm

Light Source Power Output

5 mW maximum continuous (CW)

Dimensions (H x W x D)

7.1 x 7.1 x 13 in (180 x 180 x 330 mm)

Chip Capacity

One 4-channel chip

Ventilation/Cooling

3‚ (77 mm) minimum space required around instrument for proper air flow

Operating Temperature

65° to 82°F (18° to 28°C)

Operating Humidity

10% to 70% RIH, noncondensing

Input Voltage

100-127/200-240V~ nominal

90-264V~ maximum operating range

Our Price: $3,995.00
2 in stock!
Agilent 2100 Bioanalyzer G2938A Agilent 2100 Bioanalyzer G2938A

Agilent 2100 Bioanalyzer G2938A Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $7,995.00