Home > Chromatography > HPLC > Agilent >

Gilson FC 203B Fraction Collector
Gilson FC 203B Fraction Collector
Click Here to View the Technical Specs for the FC-203B
 
Alternative Views:


Our Price: $1,325.00

Condition: Fully Refurbished and Tested to Manufacturer Specifications
Warranty: 90-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 7 Business Days

Request a Formal Quote


Quantity in Stock:1
Product Code: GFC203B
Qty:

Description
Refurbishment Protocol
Technical Specification Sheet (NEW)
 

Gilson FC 203B Fraction Collector


The Gilson FC 203B Fraction Collector is an ideal compact fraction collector for a wide variety of collection samples, including microplates, vials, and tubes. Built-in keypad makes setup and operation simple and efficient, with easy connection to your HPLC system. Fractions can be collected by time, drop, or peak to suit your chromatography conditions.

All of our equipment is fully tested to perform at factory specifications before being shipped.

Included with the Gilson FC 203B Fraction Collector:
Includes: > Power Cord > Full 90 Day Parts and Labor Warranty

Gilson FC 203B Fraction Collector Specifications

3-Way Valves

3-port, PTFE, 67 µL internal volume, 3.5 µL dead volume from common port to the normally closed port, up to 20 mL/min with standard or large bore needle

Communication Interface

GSIOC; Inputs for start/advance and end/home; event mark output; one programmable output for control of peripheral devices

Data Acquisition

An input channel for analog-to-digital conversion; digital data is transmitted on the GSIOC

Detector Input

±100 mV full scale

Drop Counting

Up to 9,999 drops per fraction

maximum rate: 20 drops/sec

Event Marker

100 ms pulse

Front Panel

Two-line, 24-character display on backlit LCD. Five command, HELP, YES, NO and 0–9 numeric hard keys; four soft keys

Maximum Collection Volume/Tube

20 mL (28 x 60 mm scintillation vials with optional Code 24 rack)

Maximum Fractions

128 (12 x 75 mm tubes with optional Code 14 rack)

Multiple-Column Collection

Simultaneous collection from up to 8

Multiple-Cycle Operation

Repetitive collection of each sample into same set of tubes or collection of each sample into different set of tubes

Number of Racks

Holds one rack

Operating Modes

Drop, Manual, Peak + Drop, Peak + Time, Time

Peak Detection

Adaptive-slope algorithm that applies user-specified parameters to accommodate drifting baselines, negative and asymmetrical peaks, or absolute threshold level that collects all peaks above specified mV value

Peak parameters: peak height or level, in mV and peak width at half-height, in minutes

Minimum peak height for fractionation: 0.1 mV full scale

Detector-collector delay: 0.01 minute increments

Power Requirements

120V, 50/60Hz, 0.5A

Programmable Time Units

From 0.01 to 99.99 minutes per tube with a 0.01 minute limit of resolution

Time-Based Programming

Up to 10 collection windows and 10 drain steps in any mode

Tube Change Time

100—250 ms, center to center, depending on rack type

Dimensions (W x D x H)

32.4 x 29.2 x 26.7 cm (12.8 x 11.5 x 10.5 in)



Gilson FC-203B Manual
Click Here to View all the Technical Specs for the FC-203B

Why Buy From Marshall Scientific?

Every product we offer undergoes a rigorous inspection process to verify that all manufacturer specifications are met. All of the electronics and boards are tested for proper function, and any necessary preventative maintenance is performed alongside repairs by our industry trained technicians. Our primary goal is to offer products that are as close to new as possible at an affordable price.

All Lab Equipment is Fully Refurbished and Tested

Most Pieces Ship within 2 to 5 Business Days

All Products Come with a Standard Warranty

Trained Customer and Technical Support

Industry Leading Overall Customer Satisfaction

Marshall Scientific's Certified Refurbishment Protocol

×

Our technicians decontaminate and clean all equipment upon arrival and upon purchase to create a neutral environment for lab use.

Preliminary testing is conducted to identify potential product defects, upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction from excessive use are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your instrument performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.

Once we finish our rigorous testing and decontamination procedures, your order will be packaged to best protect it during shipment and will include delivery insurance.


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Chromatography > HPLC > Agilent
Chromatography
Chromatography > HPLC
Chromatography > HPLC > Agilent > Fraction Collectors