Home > Chromatography > HPLC > Agilent
Choose a sub category:
Auto Samplers Degassers Detectors
Fraction Collectors Pumps Systems
Thermal Controllers
Sort By:
Page of 9
Agilent 1100 G1323B HPLC Gameboy Controller Agilent 1100 G1323B HPLC Gameboy Controller

Agilent 1100 G1323B HPLC Gameboy Controller


The Agilent 1100 G1323B Gameboy HPLC Controller is for use with HP/Agilent 1100 and 1200 HPLC systems. The Agilent hand-held control module self-configures all modules for total system control using controller-area network (CAN) communication and cabling. All instrument control parameters including column ID can be stored on credit-card sized PCMCIA (PC) cards for error-free transfer between instruments. A liquid-crystal display allows online monitoring of the signal during the run.

Our Price: $625.00
Deal of the Month Price: $475.00
Money Saved: $150.00
Agilent 1100 HPLC G1322A Degasser Agilent 1100 HPLC G1322A Degasser

Agilent 1100 HPLC G1322A Degasser Specifications

Max Flow Rate

10 ml/min per channel

Reduced performance above 5 ml/min

Number of Channels

4

Internal Volume

1 ml/channel

Materials in Contact with Solvent

PTE, PEEK

pH Range

1 – 14

Analog Output (AUX)

For pressure monitoring, range 0 – 3 V

Dimensions (W x D x H)

13.5 x 17 x 3.1 in (345 x 435 x 80 mm)

Electrical Requirements

100-120 or 220-240 VAC, 50/60 Hz

Our Price: $1,995.00
HP Agilent 1100 HPLC G1322A Degasser HP Agilent 1100 HPLC G1322A Degasser

HP Agilent 1100 HPLC G1322A Degasser Specifications

Max Flow Rate

10 ml/min per channel

Reduced performance above 5 ml/min

Number of Channels

4

Internal Volume

1 ml/channel

Materials in Contact with Solvent

PTE, PEEK

pH Range

1 – 14

Analog Output (AUX)

For pressure monitoring, range 0 – 3 V

Dimensions (W x D x H)

13.5 x 17 x 3.1 in (345 x 435 x 80 mm)

Electrical Requirements

100-120 or 220-240 VAC, 50/60 Hz

Our Price: $1,995.00
Agilent 1100 HPLC System w/ DAD Detector Agilent 1100 HPLC System w/ DAD

Refurbished Agilent 1100 System
Included with the Agilent 1100 HPLC System w/ DAD:
Includes:

G1311A Quat Pump (Binary Pump Available)
G1313A Autosampler (G1329A Thermal Autosampler & Therm Available)
G1315B DAD Detector
G1316A Column Compartment
G1379A Degasser (G1322a Degasser Available)
G1323B Gameboy Controller

Windows 10 Professional 64-Bit Data Station with Flatscreen Monitor
Chemstation version 4.3 software
Lab Advisor software B.02.10

All Power Cords > Can/Crossover Cables > Lan Interface Card > Solvent Tubing > Capillaries > Full 90 Day Parts and Labor Warranty


Agilent 1100 HPLC System with DAD Detector Specifications

Our Price: $17,795.00
HP Agilent 1100 HPLC G1329A Autosampler HP Agilent 1100 HPLC G1329A Autosampler

HP Agilent 1100 HPLC G1329A Autosampler Specifications

GLP Features

Early maintenance feedback (EMF), electronic records of maintenance and errors

Communications

Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output

Safety Features

Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display

Injection Range

0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification

required)

Replicate Injections

1 – 99 from one vial

Precision

Typically < 0.5 % RSD of peak areas from 5 – 100 µl

Typically < 1 % RSD of peak areas from 1 – 5 µl

Minimum Sample Volume

1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial

Carryover

Typically < 0.1 %, < 0.05 % with external needle cleaning

Sample Viscosity Range

0.2 – 50 cp

Replicate Injections Per Vial

1 – 99

Sample Capacity

100 × 2-ml vials in 1 tray

40 × 2-ml vials in ½ tray

15 × 6-ml vials in ½ tray (Agilent vials only)

Injection Cycle Time

Typically 50 s depending on draw speed and injection volume

Our Price: $4,295.00