4.8
Customer Reviews
Skip to content
To take full advantage of this site, please enable your browser's JavaScript feature.
Learn how
You're Viewing Our Recertified Equipment
|
Click Here to Switch to Our New Equipment
What's included
Specs
Testimonials
Recert Protocol
MarshallCare™
Add to Cart
Request A Formal Quote
About Us
My Account
My Cart
(603) 601-8511
www.MarshallScientific.com
Menu
Specials
Home
Categories
Services
Equipment Repair Request Form
Lab Equipment
Return and Refund Policy
RPM to RCF Calculator
Cannabis Testing Equipment
Rotor Compatibility Guide
View New Equipment
Contact Us
603-601-8511
About Us
Sustainability
Our Team
Testimonials
Careers
Sell Equipment
Lab Liquidation
Financing
Startup Packages
My Account
Most Products Ship Fast & Free!
Equip Yourself Sooner:
View Details
Need Instrument Repair Services?
Fast & Cost-Effective Solutions Available:
Contact Us
Take Advantage of our Acclaimed Chat Support Today!
Always Powered by Humans:
Start Chatting
Equipment Categories
Analyzers
Aspirators
Autoclaves
Balances
Cell Counters
Cell Disruptors
Centrifuges
Centrifuge Rotors
Centrifuge Adapters
Rotor Buckets
Chromatography - HPLC
HPLC Systems
HPLC Components
Chromatography - FPLC
FPLC Systems
FPLC Components
Circulating Chillers
Chiller Pumps
Climate Chambers
Cytometers
Dry Bath Heaters
Electrophoresis Power Supplies
Evaporators - Blowdown
Evaporators - Centrifugal
Cold Traps
Evaporator Rotors
Evaporators - Rotary
Diaphragm Vacuum Pumps
Evaporating Systems
Heating Baths
Vacuum Controllers
Freeze Dryer Systems
Freeze Dryer Accessories
Freezers
Glassware Washers
Heated Circulators
Histology
Centrifuges
Microscopes
Microtomes
Slide Stainers
Slide Warmers
Homogenizers
Dismembrators & Sonifiers
Hot Plates Stirrers
Imaging Systems
Incubators
Incubator Shakers
Lab Refrigerators
Lab Furniture
Mass Spectrometry
Microplate Readers
Microplate Washers
Microscopes
Mills & Grinders
Mixers
Moisture Analyzers
Oscilliscopes
Ovens
Ozone Generators
Peristaltic Pumps
pH Meters
Pipettes
Rheometers
Shakers
Spectrophotometers
Thermal Cyclers / PCR
Thermal Cycler Blocks
Real-Time PCR Systems
Thermal Mixers
Turbidimeters
Ultrasonic Cleaners
Vacuum Concentrators
Vacuum Pumps
Vortexers
Water Baths
Home
>
Block Configuration
>
96-Well Sample Block
Find by Brand
ABI (2)
Biorad (1)
Find by Maximum RT-PCR Ramp Rate
2.5C per Second (1)
5.0C per Second (1)
6.5C per Second (1)
Sort By:
Price: Low to High
Price: High to Low
Most Popular
Title
Manufacturer
Newest
Oldest
Availability
30 per page
60 per page
120 per page
180 per page
300 per page
Page
of 1
Applied Biosystems 7500 Real-Time PCR System
Applied Biosystems 7500 Real-Time PCR System Specifications
Block Configuration
96-Well (20 to 100 uL reactions)
Temperature Range
4°C to 100°C
Temperature Uniformity
± 0.5°C (30 seconds after clock start)
Temperature Accuracy
± 0.25°C of setpoint/display temperature (measured at 3 minutes after clock start)
Maximum Ramp Rate
2.5°C/second
Run Time
< 2 hours
Optical System
CCD camera with halogen lamp excitation; five-exciation and five-emission filters
Dynamic Range
9 logs of linear dynamic range
Sensitivity
Detection of 1 copy of template in 50 uL reaction for a single reporter TaqMan assay, with 99.7% confidence
Multiplexing
Up to 5 targets per well
Dimensions (W x D x H)
13.9 x 17.7 x 19.3 in. (34 x 45 x 49 cm)
Weight
75 lb. (34 kg)
Electrical Requirements
100-240V, 50/60Hz, 1080W
Our Price
:
$7,495.00
Biorad CFX Connect Real-Time PCR System
Biorad CFX Connect Real-Time PCR System Specifications
Block Configuration
96-Well (1 to 50 uL reactions, recommended for 10 to 25 uL reactions)
Temperature Range
0°C to 100°C
Temperature Uniformity
± 0.4°C well-to-well within 10 seconds of arrival at 90°C
Temperature Accuracy
± 0.2°C of programmed target at 90°C
Maximum Ramp Rate
5°C/second
Average Ramp Rate
3.3°C/second
Gradient Operational Range
30°C to 100°C
Gradient Programmable Span
1°C to 24°C
Scan Time
12 seconds (all channels), 3 seconds (FAM only)
Excitation Source
3 filtered LEDs
Detection Channels
3 filtered photodiodes
Range of Excitation/Emission Wavelengths
450 to 580 nm
Dynamic Range
10 orders of magnitude
Sensitivity
Detects 1 copy of target sequence in human genomic DNA
Multiplexing
Up to 2 targets per well
Dimensions (W x D x H)
13 x 18 x 14 in. (33 x 46 x 36 cm)
Weight
47 lb. (21 kg)
Electrical Requirements
100-240V, 50/60Hz
Our Price
:
$9,995.00
Applied Biosystems QuantStudio 5 Real-Time PCR System w/ 96-Well Sample Block
Applied Biosystems QuantStudio 5 Real-Time PCR System w/ 96-Well Sample Block Specifications
Block Configuration
96-Well (10 to 100 uL reactions)
Maximum Ramp Rate
6.5°C/second
Average Sample Ramp Rate
3.66°C/second
Temperature Uniformity
± 0.4°C
Run Time
Less than 30 minutes
Heating and Cooling Method
Peltier
Excitation (Light Source)
Bright white LED
Filters or Colors
6 decoupled filters
Excitation and Detection Range
450 to 680 nm and 500 to 730 nm
Multiplexing
Up to 6 targets
Dynamic Range
10 logarithmic units
Sensitivity (Resolution)
Detect differences as small as 1.5-fold in target quantities in a singleplex reaction
Data Acquisition
Whole-plate imaging
Onboard Memory
10 GB, which translates to approximately 2,000 to 5,000 run files
Electrical Requirements
100-240V, 50/60Hz
Our Price
: