Agilent 1200 HPLC G1364C Fraction Collector Agilent 1200 HPLC G1364C Fraction Collector

Agilent 1200 HPLC G1364C Fraction Collector Specifications

Trigger Modes

Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)

Operating Modes

Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste

Test Tube/Plate Sizes

Minimum 48 mm to 75 mm maximum

Maximum Tube Volume

ca. 45 ml

Maximum Flow Rate

100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)

Delay Volumes [μl]

Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)

Diverter valve: ~15

Diverter valve to needle: ~110

Needle: -~5

Delay Calibration Sensor

Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode

Diverter Valve

3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar

Maximum Capacity

3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve

Interfaces

Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves

Safety Features

Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Our Price: $6,695.00
Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector

Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector Specifications

Delay Volume (in ul)

Fraction collector inlet to diverter valve: ~50 (typical, depends on length of the tubing)

Diverter valve: ~15

Diverter valve to needle: ~10

Needle: ~4

Maximum System Flow 10 mL/min
Maximum Collection Volume

~20 mL with 30 x 48 mm (OD x L) tube

~30 mL with 30 x 75 mm (OD x L) tube

Maximum Capacity 3 fraction collectors in parallel plus one recovery fraction collector
Trigger Modes

Time slices

Peak (threshold, up- / downslope)

Timetable (combination of time intervals and peak)

Manual trigger (supported only with Agilent Instant Pilot G4208A)

Maximum Pressure 6 bar at the diverter valve during switching
Plates/Trays 4 x well-plates full tray (MTP), only one type of well-plates can be used at a time in one tray
Maximum Tube Height

48 mm with long needle assembly G1367-87200

75 mm with short needle assembly G1364-87202

Our Price: $8,995.00
Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector

Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector Specifications

Delay Volume (in ul)

Fraction collector inlet to diverter valve: ~500 (typical, depends on length of the tubing)

Diverter valve: ~15

Diverter valve to needle: ~110

Needle: ~5

Maximum System Flow 100 mL/min
Maximum Capacity 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-position, 13-port selector valve (PN G1160A)
Trigger Modes

Time slices

Peak (threshold, up- / downslope)

Timetable (combination of time intervals and peak)

Manual trigger (supported only with Agilent Instant Pilot G4208A)

Operating Modes

Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position

Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste

Included Tray Full tray with 215 test tubes (12 mm OD, max. height 100 mm, ~7 ml / tube)
Electrical Requirements 100-240V, 50/60Hz

Our Price: $8,395.00
Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector

Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector Specifications

Delay Volume (in ul)

Fraction collector inlet to diverter valve: ~50 (typical, depends on length of the tubing)

Diverter valve: ~15

Diverter valve to needle: ~10

Needle: ~4

Maximum System Flow 10 mL/min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve). The analytical scale fraction collector can be modified for flow rates > 10 ml/min
Maximum Collection Volume

~20 mL with 48 mm tubes

~30 mL with 75 mm tubes

Maximum Capacity 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve (PN G1160A)
Cooling Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
Trigger Modes

Time slices

Peak (threshold, up- / downslope)

Timetable (combination of time intervals and peak)

Manual trigger (supported only with Agilent Instant Pilot G4208A)

Trigger Sources Agilent 1260 Infinity DAD/MWD detectors (G1315C,D; G4212B/ G1365 C,D), the Agilent 1260 Infinity Fluorescence Detector (G1321A) and the Agilent G1946C/D, G1956A/B LC-MSD are fully supported
Operating Modes

Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position

Continuous flow: optional, available only when using deep well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste

Needle into location: Needle pushes into the vessel as deep as specified, for the use with capped vials and test tubes and well plates with closing mats

Droplet setup mode: The tip of the fraction collector needle will initially move down to the bottom of the well. Then it will slowly move upwards while the fraction is collected. The droplet setup mode enables the fraction collector to collect small fractions without bubbles

Diverter Valve 3/2 valve, with switching time < 100 ms
Maximum Pressure 6 bar at the diverter valve during switching
Plates/Trays

4 x well-plates full tray (MTP)*

2 x well-plates std. tray + 10 funnels with external containers* (+ 1 half tray)

2 × well-plates std. tray (MTP) + 10 × 2 ml vials* (+ 1 half tray)

100 x 2 ml in std. tray (+ 1 half tray)*

3 x 40 x 2 ml in half tray*

3 x 40 funnels in half tray

3 x 15 x 6 ml in half tray*

Full tray with 40 test tubes (30 mm OD, max. height 48 mm, ~20 ml vol.)

Full tray with 60 test tubes (25 mm OD, max. height 48 mm

Full tray with 126 test tubes (16 mm OD, max. height 48 mm)

Full tray with 215 test tubes (12 mm OD, max. height 48 mm)

Maximum Tube Height

48 mm with long needle assembly G1367-87200

75 mm with short needle assembly G1364-87202

Delay Calibration Sensor Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
Diverter Valve 3/2 Diverter Valve with low internal volume (15 ul), switching time < 100 ms, maximum operating pressure 6 bar

Our Price: $7,495.00