Home > HPLC Component Type > HPLC Pumps
Sort By:
Page of 1
Agilent 1200 HPLC G1312B SL Binary Pump Agilent 1200 HPLC G1312B SL Binary Pump

Hydraulic system Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
Setable flow range 0.001 to 10 mL/min, in 0.001 mL/min increments
Flow range 0.05 to 10.0 mL/min
Flow precision < 0.07% RSD or < 0.02 min SD, whatever is greater based on retention time at constant ambient temperature
Flow accuracy ± 1% or 10 µl/min whatever is greater
Pressure Operating range 0 400 bar (0 to 5880 psi) up to 5 ml/min
Pressure pulsation < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH range 1.0 to 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient formation High-pressure binary mixing, delay volume 180 ‚ 480 µl without mixer, 600 to 900 µl with mixer, dependent on back pressure
Composition range 1 to 99 % or 5 µl/min per channel, whatever is greater
Composition precision < 0.5% absolute
Composition accuracy ± 0.15% RSD, at 1 ml/min

Our Price: $7,050.00
Sale Price: $5,495.00
Money Saved: $1,555.00
Free Shipping
Agilent 1200 HPLC G1311A Quat Pump Agilent 1200 HPLC G1311A Quat Pump

Agilent 1200 HPLC G1311A Quat Pump Specifications

Setable Flow Range

0.001 to 10 ml/min, in 0.001 ml/min increments

Flow Range

0.2 to 10.0 ml/min

Flow Precision

< 0.07% RSD, or < 0.02 min SD whatever is greater, based n retention time at constant room temperature

Flow Accuracy

± 1% or 10 µl/min whatever is greater

Pressure

Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min

Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min

Pressure Pulsation

< 2% amplitude (typically < 1%), at 1 ml/min isopropanol, at all pressures > 1 MPa (10 bar)

Recommended pH Range

1.0 to 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel

Gradient Formation

Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve

Delay volume 800 – 1100 µl, dependent on back pressure

Composition Range

0 to 95% or 5 to 100%, user selectable

Composition Precision

< 0.2% SD, at 0.2 and 1 ml/min

Dimensions (H x W x D)

5.5 x 13.5 x 17 in

Electrical Requirements

100-120 or 22-240 VAC, 50/60 Hz, 220 VA

Our Price: $6,950.00
Sale Price: $6,230.00
Money Saved: $720.00
Free Shipping
Agilent 1260 Infinity I HPLC G1311B Quat Pump Agilent 1260 Infinity I HPLC G1311B Quat Pump

Agilent 1260 Infinity HPLC G1311B Quat Pump Specifications

Setable Flow Range

0.001 to 10 mL/min, in 0.001 mL/min increments

Flow Range

0.2 to 10.0 mL/min

Flow Precision

≤ 0.07% RSD, or ≤ 0.02 min SD whatever is greater, based on retention time at constant room temperature

Flow Accuracy

± 1% or 10 µl/min whatever is greater

Pressure Operating Range

0 to 60 MPa (0 – 600 bar, 0 – 8,700 psi) up to 5 mL/min

0 to 20 MPa (0 – 200 bar, 0 – 2,950 psi) up to 10 mL/min

Pressure Pulsation

< 2% amplitude or < 3 bar at 1 mL/min isopropanol, at all pressure > 1 MPa (10 bar, 145 psi)

Recommended pH Range

1.0 to 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel

Gradient Formation

Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve

Delay Volume 600 to 900µl, dependent on back pressure

Composition Range

0 to 95% or 5 to 100%, user selectable

Composition Precision

< 0.2% RSD or < 0.04 min SD

Integrated Degassing Unit Number of channels: 4

Internal volume per channel: 1.5 mL

Electrical Requirements

100 to 240V, 50/60 Hz, 180 VA

Our Price: $9,050.00
Sale Price: $8,510.00
Money Saved: $540.00
Free Shipping
Agilent 1100 HPLC G1312A Binary Pump Agilent 1100 HPLC G1312A Binary Pump

Agilent 1100 HPLC G1312A Binary Pump Specifications

Setable Flow Range

Setpoints 0.001 to 5 ml/min, in 0.001 ml/min increments

Flow Range

0.1 to 5 ml/min

Flow Precision

< 0.07% RSD or < 0.02 min SD

Flow Accuracy

± 1% or 10 ul/min

Pressure

Operating range 0 to 400 bar (0 to 5880 psi) up to 5 ml/min

Pressure Pulsation

< 2% amplitude (typically < 1%) at 1 ml/min isopropanol, at all pressures > 1 MPa

Compressibility Compensation

User-selectable, based on mobile phase compressibility

Hydraulic System

Two dual pistons in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve

Recommended pH Range

1.0 to 12.5; solvents with pH < 2.3 should not contain acides with attack stainless steel

Gradient Formation

High-pressure binary mixing, delay volume 180 to 480 ul without mixer, 600 to 900 ul with mixer, dependent upon back pressure

Composition Range

1 to 99% or 5 ul/min per channel

Composition Precision

< 0.5% absolute

Composition Accuracy

< 0.15% RSD at 1 ml/min

Our Price: $5,000.00
Sale Price: $3,950.00
Money Saved: $1,050.00
Free Shipping
Agilent 1100 HPLC G1311A Quat Pump Agilent 1100 HPLC G1311A Quat Pump

Agilent 1100 HPLC G1311A Quat Pump Specifications

Setable Flow Range

0.001 to 10 ml/min, in 0.001 ml/min increments

Flow Range

0.2 to 10.0 ml/min

Flow Precision

< 0.3% RSD (usually 0.15%), based on retention time, at 1 ml/min

Pressure

Operating range 0 to 40 MPa (0 to 400 bar, 0 to 5880 psi) up to 5 ml/min

Operating range 0 to 20 MPa (0 to 200 bar, 0 to 2950 psi) up to 10 ml/min

Pressure Pulsation

< 2% amplitude (typically < 1%), at 1 ml/min isopropanol, at all pressures > 1 MPa (10 bar)

Recommended pH Range

1.0 to 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel

Gradient Formation

Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve

Delay volume 800 to 1100 µl, dependent on back pressure

Composition Range

0 to 95% or 5 to 100%, user selectable

Composition Precision

< 0.2% SD, at 0.2 and 1 ml/min

Dimensions (H x W x D)

5.5 x 13.5 x 17 in

Electrical Requirements

100 to 120 or 22 to 240 VAC, 50/60 Hz, 220 VA

Our Price: $5,050.00
Sale Price: $3,750.00
Money Saved: $1,300.00
Free Shipping
Agilent 1260 Infinity I HPLC G1312B Binary Pump Agilent 1260 Infinity I HPLC G1312B Binary Pump

Agilent 1260 Infinity HPLC G1312B Binary Pump Specifications

Hydraulic System Two dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons
Setable Flow Range 0.001 to 5 mL/min, in 0.001 mL/min increments
Flow Range 0.05 to 5.0 mL/min
Flow Precision < 0.07% RSD or < 0.02 min SD, whatever is greater
Flow Accuracy ± 1% or 10 µl/min, what ever is greater
Pressure Operating Range 0 to 60 MPa (0 to 600 bar, 0 to 8,700 psi) up to 5 mL/min
Pressure Pulsation < 2% amplitude or < 3 bar at 1 mL/min isopropanol, at all pressures > 1 MPa (10 bar, 147 psi)
Compressibility Compensation Pre-defined, based on mobile phase compressibility
Recommended pH Range 1.0 to 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient Formation High-pressure binary mixing
Delay Volume ± 1% or 10 µl/min, what ever is greater

Low delay volume configuration: 120 µl

Our Price: $8,740.00
Sale Price: $6,995.00
Money Saved: $1,745.00
Free Shipping
Agilent 1260 Infinity II HPLC G7112B Binary Pump Agilent 1260 Infinity II HPLC G7112B Binary Pump

Agilent 1260 Infinity II HPLC G7112B Binary Pump Specifications

Hydraulic System Two dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons
Settable Flow Range 0.001 - 5.0 ml/min, in 0.001 ml/min increments
Recommended Flow Range

0.05 - 5.0 ml/min

Flow Precision ≤ 0.07% RSD or ≤ 0.02 min SD, whichever is greater
Flow Accuracy ± 1% or 10 µl/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)
Pressure Operating Range

Up to 60 MPa (600 bar, 8700 psi) up to 5 ml/min

Pressure Pulsation < 2% amplitude (typically < 1.3%) or < 0.3 MPa (3 bar, 44 psi), whichever is greater
Compressibility Compensation Pre-defined, based on mobile phase compressibility
Recommended pH Range 1.0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient Formation High-pressure binary mixing
Delay Volume 600 - 900 µl, dependent on back pressure; measured with water at 1 ml/min (water/caffeine tracer)
Settable Composition Range 0 - 100%
Recommended Compostion Range 1 - 99% or 5µl/min per channel, whichever is greater
Composition Precision < 0.15% RSD or < 0.04 min SD, whatever is greater
Integrated Degassing Unit

Number of channels: 2

Internal volume per channel: 0.45 ml

Our Price: $9,550.00
Sale Price: $8,450.00
Money Saved: $1,100.00
Free Shipping
Agilent 1260 Infinity II HPLC G7111B Quat Pump Agilent 1260 Infinity II HPLC G7111B Quat Pump

Agilent 1260 Infinity II HPLC G7111B Quat Pump Specifications

Settable Flow Range Set points 0.001 to 10 ml/min, in 0.001 ml/min increments
Flow Range 0.2 to 10.0 ml/min
Flow Precision ≤ 0.07% RSD, or ≤ 0.02 min SD whatever is greater, based on retention time at constant room temperature
Flow Accuracy ± 1% or 10 µl/min, whatever is greater, pumping degassed H2O at 10 MPa (100 bar)
Pressure Operating Range

Operating range up to 60 MPa (600 bar, 8700 psi) up to 5 ml/min

Operating range up to 20 MPa (200 bar, 2950 psi) up to 10 ml/min

Pressure Pulsation < 2% amplitude (typically < 1.0%) or < 0.3 MPa (3 bar, 44 psi), whatever is greater, at 1 ml/min isopropanol, at all pressures > 1 MPa (10 bar, 145 psi)
Recommended pH Range 1.0 to 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient Formation Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve
Delay Volume 600 to 900 µl, dependent on back pressure; measured with water at 1 ml/min
Composition Range 0 to 100% in 0.1% increments
Composition Precision < 0.2% RSD or < 0.04 min SD, whatever is greater, at 1 ml/min; based on retention time at constant room temperature
Integrated Degasser

Number of channels: 4

Internal volume per channel: 1.5 ml

Dimensions (H x W x D) 7.1 x 15.6 x 17.2 in. (18 x 39.6 x 43.6 cm)
Electrical Requirements 100 to 240 V, 50/60 Hz, 80 VA

Our Price: $9,750.00
Sale Price: $8,650.00
Money Saved: $1,100.00
Free Shipping
Agilent 1290 Infinity I HPLC G4220A Binary Pump Agilent 1290 Infinity I HPLC G4220A Binary Pump

Agilent 1290 Infinity I HPLC G4220A Binary Pump Specifications

Hydraulic System Two dual-piston in-series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, and smooth motion control of pistons for active damping
Settable Flow Range 0.001 to 5.0 mL/min, in 0.001 mL/min increments
Flow Precision ≤ 0.07 % RSD or 0.005 min SD, whatever is greater (0.2 to 5.0 mL/min)
Flow Accuracy ± 1 % or 10 uL/min, whichever is greater. Pumping degassed H2O at 10 MPa (100 bar)
Pressure Operating Range Up to 120 MPa (1200 bar) at up to 2 mL/min; 80 MPa (800 bar) at 5 mL/min
Pressure Pulsation <1 % amplitude or < 0.5 MPa (5 bar), whichever is greater
Gradient Formation High-pressure binary mixing
Delay Volume Jet Weaver V35: < 45 uL; Jet Weaver V100: <75 uL. For lowest delay volumes, the Jet Weaver can be removed
Settable Composition Range Settable range: 0 to 100 %; Recommended Range 1 – 99 % or 5 ul/min per channel, whichever is greater
Composition Precision < 0.15 % RSD or 0.01 min SD, whatever is greater
Integrated Degassing Unit Number of channels: 2; Internal volume per channel: 1.5 mL

Our Price: $9,725.00
Free Shipping
Agilent 1260 Infinity II HPLC G7104C Flexible Pump Agilent 1260 Infinity II HPLC G7104C Flexible Pump

Agilent 1260 Infinity II HPLC G7104C Flexible Pump Specifications

Settable Flow Range 0.001 to 5 ml/min, in 0.001 ml/min increments
Flow Precision ≤ 0.07 % RSD or 0.01 min SD, whichever is greater
Flow Accuracy ± 1 % or ± 10 uL/min, whichever is greater
Pressure Operating Range Up to 80 MPa (800 bar, 11603 psi) up to 5 mL/min
Pressure Pulsation < 1 % amplitude or < 0.5 MPa (5 bar), whichever is greater
Recommended pH Range 1.0 to 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient Formation Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve
Delay Volume ≤ 350 µL (default configuration)
Composition Range Settable range: 0 to 100 %
Recommended range: 1 to 99 %
Composition Precision < 0.15 % RSD or 0.02 min SD, whichever is greater
Integrated Degassing Unit Number of channels: 4 Internal volume per channel: 1.5 ml

Our Price: $9,995.00