Type
Specification
Weight
0.8 kg
Dimensions (width x depth x height)
130 x 225 x 35 mm (5.1 x 8.9 x 1.4 inches)
Line voltage
22 VDC, ± 10 %
Power consumption
6 W / 20.5 BTU/hour
Ambient operating temperature
0 to 55C (32 to 131F)
Ambient non-operating temperature
-40 to 70C (-40 to 158F)
Humidty
< 95%, at 25 ‚ 40C (77 to 104F)
Operating Altitude
Up to 2000 m (6562 ft)
Non-operating altitude
Up to 4600 m (15092 ft)
Safety standards: IEC, CSA, UL, EN
Installation category II, pollution degree 2. For indoor use only. Research Use Only. Not for use in Diagnostic Procedures.
Setable Flow Range
0.001 to 10 ml/min, in 0.001 ml/min increments
Flow Range
0.2 to 10.0 ml/min
Flow Precision
< 0.07% RSD, or < 0.02 min SD whatever is greater, based n retention time at constant room temperature
Flow Accuracy
± 1% or 10 µl/min whatever is greater
Pressure
Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min
Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min
Pressure Pulsation
< 2% amplitude (typically < 1%), at 1 ml/min isopropanol, at all pressures > 1 MPa (10 bar)
Recommended pH Range
1.0 to 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
Gradient Formation
Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve
Delay volume 800 – 1100 µl, dependent on back pressure
Composition Range
0 to 95% or 5 to 100%, user selectable
Composition Precision
< 0.2% SD, at 0.2 and 1 ml/min
Dimensions (H x W x D)
5.5 x 13.5 x 17 in
Electrical Requirements
100-120 or 22-240 VAC, 50/60 Hz, 220 VA
10 fg Anthracene, Ex=250 nm, Em=400 nm
RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)
RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime
Range: settable 200 - 700 nm and zero-order
Bandwidth: 20 nm (fixed)
Monochromator: concave holographic grating, F/1.6, blaze: 300 nm
Range: settable 280 - 900 nm and zero-order
Monochromator: concave holographic grating, F/1.6, blaze: 400 nm
Repeatability: ± 0.2 nm
Accuracy: ± 3 nm setting
Trigger Modes
Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
Operating Modes
Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
Test Tube/Plate Sizes
Minimum 48 mm to 75 mm maximum
Maximum Tube Volume
ca. 45 ml
Maximum Flow Rate
100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
Delay Volumes [μl]
Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
Diverter valve: ~15
Diverter valve to needle: ~110
Needle: -~5
Delay Calibration Sensor
Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
Diverter Valve
3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
Maximum Capacity
3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
Interfaces
Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
Safety Features
Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors
5 minutes from ambient to 40°C
10 minutes from 40°C to 20°C