Thermo Scientific SuperSealer, Cat. #: 4110-11
Processing Speed 10 to 15 seconds/plate, block or rack of tubes
Component Compatibility Microplates, blocks and storage tube racks
Compatible Sealing Options Thermo Scientific Matrix SepraSeal mats,
CapMats, and the SuperSealer Adhesive
Seal Mat
- Automatically seals plates, blocks, and tube racks of nearly any height with no manual adjustments
- Provides consistent and reliable sealing for sample storage and liquid handling applications
- Compatible with Thermo Scientific Matrix SepraSeal mats for liquid handling and single-tube access
- Works with Matrix CapMats for complete plate and block sealing during storage
- Simple drawer-loading operation
- Ensures uniform seal integrity across a wide range of plate and block formats
- Reduces manual handling errors and improves lab workflow efficiency
The Thermo Scientific SuperSealer, Cat. #: 4110-11 provides incredible efficiency in the sealing of microplates, blocks, and storage tube racks. Compatible with use of multiple Thermo Scientific sealing options to ensure versatility for laboratories working with a variety of vessel types. With its optimized design, the Thermo Scientific SuperSealer is capable of sealing vessels of almost any height with no adjustments necessary. Engineered for ease of operation, users can simply place their chosen component into the drawer, and close the door to begin sealing.
Thermo Scientific Matrix Sealing options are required for operation, and not included with purchase of the Thermo Scientific SuperSealer, Cat. #: 4110-11.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Thermo Scientific SuperSealer, Cat. #: 4110-11
includes:
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific SuperSealer, Cat. #: 4110-11
Specifications
|
Processing Speed
|
10 to 15 seconds/plate, block or rack of tubes
|
|
Dimensions (W x D x H)
|
6.5 x 12.5 x 13.5 in. (16.5 x 31.75 x 34.3 cm)
|
|
Weight
|
30 lbs. (13.5 kg)
|
|
Electrical Requirements
|
24 VDC, 2.1A
|
- Install new waste and buffer bottles to ensure proper fluid containment and system functionality.
- Integrate a new pump into the system, verifying compatibility and secure connections.
- Verify that the power supply and PCB output the correct voltages for reliable component operation.
- Conduct a self-test on the microplate washer, evaluating all operational parameters.
- Inspect the X-axis motor belt for signs of wear, such as tears, frays, or breakages, replacing if necessary.
- Examine dispense and aspirate tubes for any damage that could affect fluid flow accuracy.
- Confirm internal pump functionality, replacing seals as needed to maintain optimal performance.
- Inspect all internal wiring for frays, tears, or breakages, addressing any faults for electrical safety.
- Verify functionality of all internal and external sensors, ensuring accurate readings across the unit.
- Disinfect the unit using an appropriate disinfection cycle to ensure sterility and safety.
- Check that residual aspiration levels are within the manufacturer’s specified limits for accuracy.
- Conduct a final cosmetic inspection to verify that all external surfaces meet appearance standards.
Technician Inspection and Recertification Checklist: Microplate Washer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
| Task |
Completed? |
Remarks? |
| Install new waste and buffer bottles | Completed | |
| Integrate new pump into system, verifying secure connections | Completed | |
| Verify power supply and PCB output correct voltages | Completed | |
| Conduct microplate washer self-test and evaluate results | Completed | |
| Inspect X-axis motor belt for wear, replacing if necessary | Completed | |
| Examine dispense and aspirate tubes for any damage | Completed | |
| Confirm internal pump functionality, replace seals as needed | Completed | |
| Inspect internal wiring for frays, tears, or breakages | Completed | |
| Verify functionality of all internal and external sensors | Completed | |
| Disinfect unit with appropriate disinfection cycle | Completed | |
| Check residual aspiration levels meet specifications | Completed | |
| Conduct cosmetic inspection for appearance standards | Completed | |
To View More of Our Recertification Protocol Click Here
|
|
 |
 |
 |
 |

|