Thermo Scientific Heraeus Multifuge X3 Centrifuge
- Intuitive control panel and digital display
- Detailed operation information, including display of set and actual parameters, maximizes run performance
- Easily adjust speed and time even during the run, with the convenient keyboard for direct input
- Innovative lid-locking technology enables one finger downward motion for easy closing and locking of centrifuge lid, even on tall benches
- Secure locking system allows easy push-button installation and exchange of rotors
- Compact size conserves workspace, and ergonomic height and curved design ensure comfortable sample handling and cleaning of unit
The Thermo Scientific Heraeus Multifuge X3 is a high-performance benchtop centrifuge engineered to deliver fast, reliable separation across a broad range of laboratory and diagnostic applications. Capable of reaching speeds up to 15,200 RPM with a maximum RCF of 25,314 x g (rotor dependent), and accommodating a maximum capacity of 4 x 1,000 mL, the centrifuge combines exceptional versatility with an unlimited runtime for uninterrupted operation. The maintenance-free induction motor ensures quiet, low-vibration performance at noise levels below 64 dB(A), even at peak speeds, delivering long-term reliability with minimal upkeep. The intuitive microprocessor-controlled panel allows precise presetting of speed, RCF value, run time, and acceleration/braking profiles — with 9 acceleration and 10 braking curves available.
Secure, dependable operation is ensured through automatic rotor recognition, electronic imbalance detection, and an automatic lid lock, while the galvanized steel chassis with steel interior and stainless steel chamber provide a durable, long-lasting build. Providing a combination of adaptability, safety and efficiency, the Thermo Scientific Heraeus Multifuge X3 Centrifuge is an impeccable solution across varying research functions.
All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Thermo Scientific Heraeus Multifuge X3 Centrifuge includes:
- > Rotor Selected Above
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific Heraeus Multifuge X3 Centrifuge Specifications
|
Maximum Speed
|
15,200 RPM
|
|
Maximum RCF
|
25,314 x g
|
|
Maximum Capacity
|
4 x 1000ml
|
|
Temperature Range
|
N/A
|
|
Maximum Kinetic Energy
|
< 62.5 kJ
|
|
Timer
|
Unlimited
|
|
Noise Level Max. Speed
|
< 64 dB (A)
|
|
Heat Dissipation
|
4776 BTU/h
|
|
Dimensions (W x D x H)
|
21.7 x 26.4 x 14.2 in. (55 x 67 x 36 cm)
|
|
Weight
|
189.6 lb. (86 kg)
|
|
Electrical Requirements
|
120V, 60Hz, 12A, 1400W
|
Click Here to Expand Rotor Specifications
|
TX-750 Rotor Specs
|
|
Capacity
|
4 x 750 mL
|
|
Max RPM
|
4,300
|
|
Max RCF
|
4,031 x g
|
|
Bioliner Rotor Specs
|
|
Capacity
|
4 x 750 mL
|
|
Max RPM
|
3,500
|
|
Max RCF
|
2,739 x g
|
|
Fiberlite F-15-8x50Cy Rotor Specs
|
|
Capacity
|
8 x 50 mL Conical tubes
|
|
Max RPM
|
14,500
|
|
Max RCF
|
24,652 x g
|
|
Fiberlite F-15-6x100Y Rotor Specs
|
|
Capacity
|
6 x 100 mL
|
|
Max RPM
|
15,000
|
|
Max RCF
|
24,652 x g
|
|
M-20 Microplate Rotor Specs
|
|
Capacity
|
2 x 3 Standard or 2 x 1 Deepwell Plates
|
|
Max RPM
|
4,000
|
|
Max RCF
|
2,272 x g
|
|
TX-1000 Rotor Specs
|
|
Capacity
|
4 x 1000 mL
|
|
Max RPM
|
4,200
|
|
Max RCF
|
4,122 x g
|
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
| Task |
Completed? |
Remarks? |
| Confirm power supply output voltages match specified requirements |
Completed |
|
| Measure and verify voltages at PCB test points for accuracy |
Completed |
|
| Confirm rotor compatibility and detection for proper identification |
Completed |
|
| Inspect exterior for cosmetic or structural damage |
Completed |
|
| Check door mechanism alignment for secure opening and closing |
Completed |
|
| Inspect and replace gas strut with OEM part as needed |
Completed |
|
| Examine rotor chamber for dents or damage and replace if necessary |
Completed |
|
| Replace and confirm functionality of all lid lock switches |
Completed |
|
| Lubricate door lock mechanism and lid lock rail for smooth operation |
Completed |
|
| Test compressor (if applicable) for proper operation and cooling |
Completed |
|
| Run 8-12 hour cycle test to ensure consistent performance |
Completed |
|
| Check rotor motor for stability, noise, and integrity |
Completed |
|
| Inspect and clear condensation drain to prevent buildup |
Completed |
|
| Verify RPM accuracy with NIST traceable tachometer and calibrate |
Completed |
|
| Check centrifuge error log for zero recorded issues |
Completed |
|
To View More of Our Recertification Protocol Click Here
|
|
 |
 |
 |
 |


|