Home > New Arrivals
Sort By:
Page of 2
Agilent 1260 Infinity II HPLC G7117C DAD Detector HS Agilent 1260 Infinity II HPLC G7117C DAD Detector HS

Agilent 1260 Infinity II HPLC G7117C DAD Detector HS Specifications

Detection Type

1024-element photodiode array
Light Source Deuterium and tungsten lamps
Number of Signals 8
Data Rate 120 Hz (both spectra and signals)
Wavelength Range 190 to 640 nm
Short Term Noise

< ± 3 x 10 -6 AU at 230/4 nm, slit width 4 nm, TC 2 s, ASTM

Drift < 0.5 x 10 -3 AU/h at 230 nm
Linearity

> 2 AU (5%) at 265 nm

Typically 2.5 AU (5%)

Wavelength Accuracy ± 1 nm
Wavelength Bunching Programmable, 2 to 400 nm in steps of 1 nm
Slit Width 1, 2, 4, 8, 16 nm
Diode Width ~ 0.5 nm

Our Price: $14,795.00
Sale Price: $12,795.00
Money Saved: $2,000.00
1 in stock!
Agilent 1260 Infinity II HPLC G7165A MWD Detector Agilent 1260 Infinity II HPLC G7165A MWD Detector

Agilent 1260 Infinity II HPLC G7165A MWD Detector Specifications

Detection Type

1024-element photodiode array
Light Source Deuterium and tungsten lamps
Number of Signals 8
Data Rate 120 Hz (both spectra and signals)
Wavelength Range 190 to 950 nm
Short Term Noise (ASTM)

< ± 0.7 x 10 -5 AU at 254 nm and 750 nm

Drift < 0.9 x 10 -3 AU/h at 254 nm
Linear Absorbance Range < 2 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 to 400 nm
Slit Width 1, 2, 4, 8, 16 nm
Diode Width < 1 nm

Our Price: $10,995.00
1 in stock!
BioTek ELx808 UV Microplate Reader - Absorbance Only BioTek ELx808 UV Microplate Reader - Absorbance Only

BioTek ELx808 UV Microplate Reader - Absorbance Only Specifications

Wavelength Range 340 to 900 nm
Wavelength Bandpass 10 nm
Wavelength Selection Filter based: 340, 405, 450, 490, and 630 nm
Microplate Capacity 96-well
Top/Bottom Read Capability N/A
Electrical Requirements 100-240V, 50/60Hz

Our Price: $4,995.00
Free Shipping 1 in stock!
Agilent 1260 Infinity I HPLC G1314F VWD Detector Agilent 1260 Infinity I HPLC G1314F VWD Detector

Agilent 1260 Infinity I HPLC G1314F VWD Detector Specifications

Detection Type

Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Noise < ± 0.25 x 10-5 AU, at 230 nm
Drift 1 x 10-4 AU/hr, at 230 nm
Linearity >2.5 AU upper limit
Wavelength Accuracy ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
Wavelength Precision < ± 0.1 nm
Slit Width 6.5nm typical over whole wavelength range

Our Price: $6,995.00
1 in stock!
Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler

Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler Specifications

Pressure Operating range 0 - 60 MPa (0 - 600 bar, 0 - 8700 psi)
GLP Features

Early maintenance feedback (EMF), electronic records of maintenance and errors

Communications Controller-area network (CAN), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety Features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display

Injection Range

0.1 – 100 µL in 0.1 µL increments (recommended 1 µl increments)

Up to 40 µL with reduced injection volume kit (hardware modification required)

Up to 1500 µl with multiple draw (hardware modification required)

Precision

< 0.25 % from 5 – 40 µL

< 0.5 % from 2 – 5 µL

< 0.7 % from 1 – 2 µL

< 1.5 % from 0.5 – 1 µL

Carryover

Typically < 0.004%

Sample Viscosity Range

0.2 – 5 cp

Metering Devices Metering pump in high pressure flow path

Sample Capacity

2 x well plates (MTP) + 10 x 2 ml vials

108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials

30 x 6 ml vials in 2 x 15 vial plate

100 Micro vial tray

54 Eppendorf tubes (0.5/1.5/2 ml) in 2 x 27 Eppendorf tube plate

Injection Cycle Time Typically < 21 s using default conditions and injections volume of 5 µL

Our Price: $7,995.00
1 in stock!
Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 208/200/240V Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 208/200/240V

Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 208/200/240V Specifications

Chamber Volume 85L (22 gal.)
Sterilization Temperature Range 105ºC to 135ºC
Chamber Dimensions (Diameter x H) 15.2 x 24.2 in. (38 x 76 cm)
Electrical Requirements 208V/220V/240V, 50/60 Hz, single phase, 3000W

Our Price: $8,995.00
1 in stock!
Thermo Scientific Steri Cycle 380 CO2 Incubator Thermo Scientific Steri Cycle 380 CO2 Incubator

Thermo Scientific Steri Cycle 380 CO2 Incubator Specifications

Temperature Range +5°C above ambient to 50°C
Temperature Uniformity ± 0.3°C at 37°C
Volume 6.5 cu. ft. (184L)
CO2 Range 1 to 20%
Internal Dimensions (W x H x D) 21.3 x 26.8 x 20.0 in. (54.1 x 68.1 x 50.8 cm)
Electrical Requirements 115V, 50/60Hz, 1PH, 9.6 FLA

Our Price: $4,995.00
1 in stock!