Home > Microplate Washers

Microplate Washers

For an overview comparison of BioTek ELx405 Microplate Washer models and their features and/or capabilities,
please view our liquid handling BioTek plate washer one-sheet.



Sort By:
Page of 2
Biotek ELx405 Microplate Washer BioTek ELx405 Microplate Washer

BioTek ELx405 Microplate Washer Specifications

Microplate Types

96-well

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96-well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds

Our Price: $3,195.00
BioTek ELX405VR Microplate Washer BioTek ELx405VR Microplate Washer

BioTek ELx405VR Microplate Washer Specifications

Microplate Types

96-well

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96-well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds

Our Price: $3,195.00
BioTek ELX405R Microplate Washer BioTek ELX405R Microplate Washer

BioTek ELx405R Microplate Washer Specifications

Microplate Types

96-well

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96-well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds

Our Price: $3,195.00
BioTek ELX405UV Microplate Washer BioTek ELX405UV Microplate Washer

BioTek ELx405UV Microplate Washer Specifications

Microplate Types

96 and 384 well plates

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96 and 384 well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds
384-wells,100 µL/well, 3 cycles: <80 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds

Our Price: $3,295.00
BioTek ELX405U Microplate Washer BioTek ELX405U Microplate Washer

BioTek ELx405U Microplate Washer Specifications

Microplate Types

96 and 384 well plates

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96 and 384 well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds
384-wells,100 µL/well, 3 cycles: <80 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds

Our Price: $3,195.00
BioTek ELX405VRS Microplate Washer BioTek ELx405VRS Microplate Washer

BioTek ELx405VRS Microplate Washer Specifications

Microplate Types

96-well

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96-well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds

Our Price: $3,195.00
Thermo Scientific Matrix Super Sealer, Cat # 4110 Thermo Scientific Matrix Super Sealer, Cat # 4110

Thermo Scientific Matrix Super Sealer, Cat # 4110

Thermo Scientific Matrix Super Sealer, Cat # 4110 in excellent condition. All of our equipment will be fully tested before shipping. Includes: > Waste & Buffer Bottles > Vacuum Pump > Power Cord > Full 90 Day Parts and Labor Warranty.

Our Price: $1,420.00