GE AKTA FPLC Explorer 10 System
GE AKTA FPLC Explorer 10 System
 
Alternative Views:


Our Price: $16,995.00

Condition: Fully Refurbished and Tested to Manufacturer Specifications
Warranty: 90-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 7 Business Days

Request a Formal Quote


Quantity in Stock:1
Product Code: AK-EX10
Qty:

Description
Refurbishment Protocol
 

GE AKTA FPLC Explorer 10 System


The GE AKTA Explorer 10 FPLC System is in excellent condition and has passed all tests for full functionality. These tests included: linking the unit to the Unicorn 5.31 operating system, testing flow rate accuracy of P-900 Pump, testing UV-900 Monitor with Nal test solution, testing pH/C-900 for functional communication with pH probe and Conductivity Cell, testing motor valves, and testing the Frac-920 for functionality through manual commands.

The GE AKTA Explorer Air 10 system
Included with the GE AKTA FPLC Explorer 10 System:
includes: P-900 Pump, UPC-900 Monitor, Mixing Chamber M-925, Conductivity Cell, pH Probe and Holder, CU-950 Control Box, Frac-920 Fraction Collector with Tube Rack, Box-900, Dell Datastation running Windows 7 Pro with Unicorn version 5.31 software, all associated communication and power cables, and Full 90 Day Parts and Labor Warranty.

GE AKTA FPLC Explorer 10 System Specifications


Frac-920 Specifications

Capacity

95 fractions in 10-18 mm tubes

Depth

400 mm

Flow Rate

< 100 ml/min

Height

250 mm

Operating Temperature

4° to 40°C

pH Stability Long Term

1 – 13

pH Stability Short Term

1 – 14

Program Memory

99 programs

Rack Designation

95 x 10-18 mm (Standard)

175 x 12 mm and 40 x 30 mm (Optional)

Relative Humidity

20 – 95% (none condensing)

Time Mode

0.01 – 9.999 min

Volume Mode

0.1 – 999 ml

Voltage

100 – 240 V

M-925 Specifications

Max Flow Rate

0.001 to 100 ml/min

Max Pressure

12ml chamber: 10 MPa at 0.1 to 100 ml/min (100 bar, 1450 psi)

0.6, 2, and 5ml chambers: 25 MPa at 0.001 to 100 ml/min (250 bar, 3625 psi)

90 ul and 0.2 ml chambers: 35 MPa at 0.001 to 5 ml/min (250 bar, 5075 psi)

pH Stability Range

1 to 13 (1 to 14 with <1 day exposure)

Viscosity

Max 5 cP

Internal Volume

6 interchangeable mixing chambers: 90 ul, 0.2, 0.6, 2, 5, and 12 ml

Mixing Principle

1 static chamber and 1 dynamic chamber

Inlet and Outlet Tubing

UNF 10 to 32 thread profile

P-900 Specifications

Flow Rate Range

Isocratic mode: 0.01 to 100 ml/min in steps of 10 ul/min

Gradient mode: 0.01 to 100 ml/min in steps of 10 ul/min

Double mode: 0.01 to 200 ml/min in steps of 10 ul/min

Pressure Range

0 to 10 MPa (100 bar, 1450 psi)

pH Stability Range

1 to 13 (1 to 14 with <1 day exposure)

Viscosity

Max 5 cP

Flow Rate Accuracy

± 2% or 20 ul/min, whichever is greater

Flow Rate Reproducibility

Flow rate 0.5 ml/min: rsd < 0.5%

Gradient Composition

Accuracy: < ±1% at 0.05 to 10 ml/min

Reproducibility: rsd < 0.25% at 0.5 to 100 ml/min

Pressure Sensor

Range: 0 to 27.5 MPa

Offset error: < 0.05 MPa

Scale error: < ±2%

Total Volume Between Inlet and Outlet

< 800 ul/module


UPC 900 Specifications
UV measurement

Absorbance range

0.01 - 5 AU (full scale)

Autozero range

-0.2 - 2.0 AU

Baseline adjust Adjustable

0-100% of full scale

Wavelengths

Hg lamp, fixed: 254 and 280

by changing filter:313, 365, 405, 436 and 546 nm

Zn lamp: 214 nm

Linearity, 5 mm cell

<3% up to 2 AU at 254 nm

<5% up to 1 AU at 280 nm

Static noise

short term: 40x10-6 AU at 254 nm

(typically 6x10-6 AU at 254 nm)

long term: 40x10-6 AU at 254 nm

Static Drift

±100x10-6 AU/h at 254 nm

Flow Sensitivity

2x10-4 AU min/ml

UV flow cell, 2nm

Flow rate

0 - 100 ml/min

Max. pressure


Why Buy From Marshall Scientific?

Every product we offer undergoes a rigorous inspection process to verify that all manufacturer specifications are met. All of the electronics and boards are tested for proper function, and any necessary preventative maintenance is performed alongside repairs by our industry trained technicians. Our primary goal is to offer products that are as close to new as possible at an affordable price.

All Lab Equipment is Fully Refurbished and Tested

Most Pieces Ship within 2 to 5 Business Days

All Products Come with a Standard Warranty

Trained Customer and Technical Support

Industry Leading Overall Customer Satisfaction

Marshall Scientific's Certified Refurbishment Protocol

×

Our technicians decontaminate and clean all equipment upon arrival and upon purchase to create a neutral environment for lab use.

Preliminary testing is conducted to identify potential product defects, upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction from excessive use are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your instrument performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.

Once we finish our rigorous testing and decontamination procedures, your order will be packaged to best protect it during shipment and will include delivery insurance.


Share your knowledge of this product. Be the first to write a review »