Fisherbrand Elite Pipette, 20 to 200uL
Adjustable or Fixed Volume Adjustable
- Extremely low plunger forces reduce hand fatigue and the risk of repetitive strain injury
- Fully autoclavable construction enables thorough sterilization and long-term durability
- Soft-touch tip ejection with geared mechanism lowers ejection force by up to 50%
- Lightweight ergonomic handle provides a secure, comfortable grip during daily use
- Super blow-out piston delivers 150% stronger air push for accurate dispensing of micro drops
- Engineered for high accuracy and precision to support reproducible results across applications
The Fisherbrand Elite Pipette, 20 to 200uL combines ergonomic comfort with precise liquid handling for reliable daily use. Designed with extremely low plunger forces, it minimizes strain and reduces the risk of repetitive stress injuries during extended pipetting sessions. The lightweight handle ensures a natural, comfortable grip, while soft-touch tip ejection with a geared mechanism cuts ejection force by up to 50% for effortless tip changes.
A fully autoclavable design allows for complete sterilization and long-term durability. The super blow-out piston delivers a 150% stronger air push compared to conventional pistons, ensuring accurate delivery of micro-volume drops. Together with high accuracy and precision across its volume range, this pipette is built to deliver consistent, dependable results in demanding laboratory workflows.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Fisherbrand Elite Pipette, 20 to 200uL includes:
- > Gravimetric Analysis Calibration Report
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Fisherbrand Elite Pipette, 20 to 200uL Specifications
|
Volume uL
|
Increment uL
|
Relative Accuracy (%)
|
Absolute Accuracy (uL)
|
Relative Precision (%)
|
Absolute Precision (uL)
|
|
20
200
|
0.2
0.2
|
± 8.0
± 0.8
|
± 1.60
± 1.60
|
≤ 3.0
≤ 0.3
|
≤ 0.60
≤ 0.60
|
- Thoroughly inspect and clean all internal components, identifying and replacing any damaged or compromised parts
- Replace all essential wear components, including O-rings, seals, tip holders, and friction rings, to ensure optimal performance
- Examine plunger and seal holders for signs of rust, wear, or damage, replacing components as necessary for operational integrity
- Verify that no leakage is present by aspirating a sample and observing for any fluid loss
- Confirm that the Mettler Toledo AB104-S balance is precisely calibrated for accurate pipette calibration measurements
- Perform a detailed gravimetric calibration, recording all findings in the comprehensive calibration report
- Ensure that all external parts are meticulously cleaned and free from any foreign contaminants
- Test the tip ejector for smooth and reliable operation, addressing any misalignment or obstruction
- Affix a dated calibration sticker to indicate recent and verified calibration
- Conduct a detailed cosmetic inspection, confirming that all surfaces and finishes meet established quality and aesthetic standards
Technician Inspection and Recertification Checklist: Pipettes
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
|
Task
|
Completed?
|
Remarks?
|
|
Thoroughly inspect and clean all internal components; replace damaged parts
|
Completed
|
|
|
Replace essential wear components like O-rings, seals, and friction rings
|
Completed
|
|
|
Examine plunger and seal holders for wear or damage; replace if needed
|
Completed
|
|
|
Verify no leakage is present by aspirating sample and checking for fluid loss
|
Completed
|
|
|
Confirm Mettler Toledo AB104-S balance calibration for accurate measurements
|
Completed
|
|
|
Perform detailed gravimetric calibration and record findings in report
|
Completed
|
|
|
Clean all external parts meticulously to remove any contaminants
|
Completed
|
|
|
Test tip ejector for smooth, reliable operation; correct misalignments
|
Completed
|
|
|
Affix dated calibration sticker to indicate verified calibration
|
Completed
|
|
|
Conduct cosmetic inspection to ensure quality of surfaces and finishes
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
 |
 |
 |
 |

|