Home > Electrophoresis

Electrophoresis

Here at Marshall Scientific we sell capillary electrophoresis systems, electrophoresis power supplies, and gel electrophoresis boxes with a multitude of different specifications capable to accommodate any lab. The electrophoresis apparatus brands that we carry include VWR, Horizon, Agilent, EC, Biorad, and Hoefer . Please have a look at our electrophoresis apparatuses that we currently have in stock and feel free to give us a call or send us an email if you have any questions.

Electrophoresis
Sort By:
Page of 1
Beckman Coulter ProteomeLab PA 800 System with UV Beckman Coulter ProteomeLab PA 800 System with UV

Beckman Coulter ProteomeLab PA 800 System with UV Specifications

Sampling Formats

96-well plates, microfuge tubes, PCR vials, 2ml vials

Temperature Range

20° below Ambient to 60°C (minimum setting 4°C)

Temperature Stability

±1°C

Temperature Accuracy

Temperature of environment: ±2°C within the range of ±15°C from ambient; ±3°C outside the range of ±15°C for ambient.

UV Source

Deuterium lamp; 30 W; prealigned

Wavelength Range

190 to 600 nm

Filter Selection

200, 214, 254, and 280 nm (standard); three open positions for additional wavelength selections; filter diameter 1/2 inch (127 mm); 0.20 in. thick

Wavelength Accuracy

2 nm

Analog Output

Output 1 is Data; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values).

Output 2 not used.

Output 3: Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed.

Electrical Requirements

100-240V, 50/60Hz; auto-voltage sensing power supply

Max Heat Dissipation to Room

400 W (1024 BTU/H)

Ambient Operation Temperature

15° to 40°C

Dimensions (W x H x D)

22.38 x 27.13 x 24.13 in (56.83 x 68.9 x 61.28 cm)

Laser Module Dimensions (W x H x D)

10.25 x 25 x 14.25 in (26.3 x 63.3 x 35 cm)

Our Price: $6,995.00
Beckman Coulter ProteomeLab PA 800 System with LIF Beckman Coulter ProteomeLab PA 800 System with LIF

Beckman Coulter ProteomeLab PA 800 System with LIF Specifications

Sampling Formats

96-well plates, microfuge tubes, PCR vials, 2ml vials

Temperature Range

20° below Ambient to 60°C (minimum setting 4°C)

Temperature Stability

±1°C

Temperature Accuracy

Temperature of environment: ±2°C within the range of ±15°C from ambient; ±3°C outside the range of ±15°C for ambient.

Relative Fluorescence Units Range

0 to 1000 RFU

Dynamic Range (at a dynamic range setting of 1000)

> 10^4

Sensitivity

1 x 10^-11M Sodium Fluorescein with a signal-to noise ratio ≥ 2

Baseline Noise

< 0.005 RFU peak to peak

Baseline Drift

< 0.2 RFU per hour

Filters (optional)

For user supplied lasers: Each laser configuration requires two filters, a laser filter to block stray laser light and an emission filter to select the wavelength of the emitted light. These filters must have an outside diameter of 0.500” (+.000, -.010”) and a thickness not greater than 0.350”; if multiple filters are used in a single channel, the total thickness cannot exceed 0.350”.

Fiber Cable Length

6 ft (1.83 m)

Software Requirements

32 Karat Software, Version 7.0 or later

Laser

3 mW 488 nm (air-cooled) Argon Ion Laser

Analog Outputs

Output 1 is Data Channel 1 and Output 2 is Data Channel 2; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values)

Output 3 is Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed

Electrical Requirements

100-240V, 50/60Hz; auto-voltage sensing power supply

Max Heat Dissipation to Room

400 W (1024 BTU/H)

Ambient Operation Temperature

15° to 40°C

Dimensions (W x H x D)

22.38 x 27.13 x 24.13 in (56.83 x 68.9 x 61.28 cm)

Laser Module Dimensions (W x H x D)

10.25 x 25 x 14.25 in (26.3 x 63.3 x 35 cm)

Our Price: $9,995.00
Thermo Scientific Owl A3-1 Large-Gel Electrophoresis System Thermo Scientific Owl A3-1 Large-Gel Electrophoresis System

Thermo Scientific Owl A3-1 Large-Gel Electrophoresis System Supply Specifications

Description

Gel size: 23 x 40cm;
Buffer volume: 4.5L; L x W x H: 53 x 32 x 11cm

Sample Range

25 to 600

Volume (Metric) Buffer

4.5L

Length x Width (Metric) Gel

40 x 23cm

Certifications/Compliance

CE Marked

Dimensions (L x W x H) Exterior

20.63 x 12.5 x 4.25 in. (53 x 32 x 11cm)

Voltage Requirements (V)

20-250

Time Requirements (hours)

1-6

Our Price: $395.00
Agilent CE Capillary Electrophoresis System Agilent CE G1600AX Capillary Electrophoresis System

Agilent CE G1600AX Capillary Electrophoresis System Specifications

Our Price: $7,205.00
Beckman P/ACE MDQ w/ LIF Capillary Electrophoresis Beckman P/ACE MDQ w/ LIF Capillary Electrophoresis System

Beckman P/ACE MDQ with LIF Capillary Electrophoresis System Specifications

Wavelength range

UV/Vis: 200, 214, 254, 280 nm
Custom filter option: 190-600 nm

Optional detectors

Diode Array or Laser Induced Fluorescence (LIF)

Sample introduction

Pressure, Vacuum, Electrokinetic

Sample temperature

5° C - 60° C

Scan collection

Diode Array 0.5 - 32Hz (user select)

Pressure range

-5 - 100 psi (rinse/seperations), -5 - 25 psi (sample introduction)

Capillary cartridge

Recirculating liquid coolant 15°C - 60°C

Data rate collection

0.5 - 32 Hz

Sample tray

61 x 96 well plates, 2 x 48 (2mL vials), 2 x 48 (0.5mL vials), or 2 x 48 (PCR vials)

Modes of operation

Constant/Gradient voltage, current & power, variable pressure

Power requirements

voltage 90 240 Vac 50/60Hz

Width

22.38 inches

Depth

24.13 inches

Height

27.13 inches / with door open 36.5 inches

Weight

132lbs

Our Price: $14,695.00
Beckman P/ACE MDQ Capillary Electrophoresis, UV Beckman P/ACE MDQ Capillary Electrophoresis System, UV

Beckman P/ACE MDQ Capillary Electrophoresis Specifications

Our Price: $9,060.00
Beckman P/ACE MDQ Capillary Electrophoresis, PDA Beckman P/ACE MDQ Capillary Electrophoresis System, PDA

Beckman P/ACE MDQ Capillary Electrophoresis, PDA Specifications

Our Price: $10,295.00