Agilent 2100 Bioanalyzer G2938C with Chip Priming Station Agilent 2100 Bioanalyzer G2938C with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $11,970.00
Caliper Life Sciences LabChip XT Fractionation System Caliper Life Sciences LabChip XT Fractionation System

Caliper Life Sciences LabChip XT Fractionation System Specifications

Fluorescence Detection Wavelength

Bandpass 547 to 750 nm

Fluorescence Data Rates

80Hz

Light Source Warmup Time

30 seconds

Light Source Excitation/Emission Wavelengths

532 nm

Light Source Power Output

5 mW maximum continuous (CW)

Dimensions (H x W x D)

7.1 x 7.1 x 13 in (180 x 180 x 330 mm)

Chip Capacity

One 4-channel chip

Ventilation/Cooling

3” (77 mm) minimum space required around instrument for proper air flow

Operating Temperature

65° to 82°F (18° to 28°C)

Operating Humidity

10% to 70% RIH, noncondensing

Input Voltage

100-127/200-240V~ nominal

90-264V~ maximum operating range

Our Price: $4,260.00
Deal of the Month Price: $3,295.00
Money Saved: $965.00
Agilent 2100 Bioanalyzer G2939A with Chip Priming Station Agilent 2100 Bioanalyzer G2939A with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $12,075.00
Agilent 2100 Bioanalyzer G2938A Agilent 2100 Bioanalyzer G2938A

Agilent 2100 Bioanalyzer G2938A Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $8,115.00
Agilent 2100 Bioanalyzer G2938B with Chip Priming Station Agilent 2100 Bioanalyzer G2938B with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution
Degree 2

Our Price: $10,925.00
GE Biacore 3000 SPR Biomolecular Interaction Analyzer GE Biacore 3000 SPR Biomolecular Interaction Analyzer

GE Biacore 3000 SPR Biomolecular Interaction Analyzer Specifications

Sample Handling

Automated sample loading and injection

Molecular Weight Detection

> 180 Da

Flow Rate Range

1 - 100 µl/min, through flow cell, steps of 1 µl

Required Sample Volume

Injected volume + 20-80 µl, depending on application

Refractive Index Range

1.33 - 1.40 (0 - 70,000 RU)

Analysis Temperature

4°C to 40°C (max 20°C below ambient)

Number of Flow Cells

4 (used individually, in series, or as 2 pairs)

Dimensions

29.9 x 13.8 x 24 in (760 x 350 x 610 mm)

Electrical Requirements

100-120V / 220-240V, 47-63 Hz, 580 VA

Our Price: $24,995.00