Caliper Life Sciences LabChip XT Fractionation System Caliper Life Sciences LabChip XT Fractionation System

Caliper Life Sciences LabChip XT Fractionation System Specifications

Fluorescence Detection

Detection Wavelength

Bandpass 547 to 750 nm

Data Rates

80Hz

Light Source

Warmup Time

30 seconds

Excitation/Emission Wavelengths

532 nm

Power Output

5 mW maximum continuous (CW)

General

Dimensions (H x W x D)

7.1 x 7.1 x 13 in (180 x 180 x 330 mm)

Chip Capacity

One 4-channel chip

Ventilation/Cooling

3” (77 mm) minimum space required around instrument for proper air flow

Environmental

Operating Temperature

65° to 82°F (18° to 28°C)

Operating Humidity

10% to 70% RIH, noncondensing

Storage Temperature

50° to 104°F (10° to 40°C)

Electrical

Power Input

1.0Arms max at 90Vac, 47-63Hz

0.6Arms max at 264Vac, 47-63Hz

Input Voltage

100-127/200-240V~ nominal

90-264V~ maximum operating range

Power Consumption

24VDC, 1.2A max

Assay Voltage

Minimum Voltage/Current

50V (limited by current)

Maximum Voltage/Current

600V (limited by current)

Barcode Reader

Barcode Engine

Motorola

Supported Barcode Types

2D Matrix

Our Price: $3,695.00
Agilent 2100 Bioanalyzer G2938B with Chip Priming Station Agilent 2100 Bioanalyzer G2938B with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution
Degree 2

Our Price: $9,780.00
Agilent 2100 Bioanalyzer G2938C with Chip Priming Station Agilent 2100 Bioanalyzer G2938C with Chip Priming Station

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $9,995.00
Agilent 2100 Bioanalyzer - model G2938A Agilent 2100 Bioanalyzer - model G2938A

Agilent 2100 Bioanalyzer Specifications

Analysis Run Time

30 to 45 min

Number of Samples

Up to 12 samples/chips

Sample Volume

1 µl

Sizing Range

50 to 7000 bp

Ambient Operating Temperature

5° to 40°C (41° to 104°F)

Electrical Requirements

100-240VAC, 50-60Hz

Power Consumption

60 VA

Dimensions (W x D x H)

162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)

Safety Standards: IEC, CSA, UL

Installation Category II, Pollution Degree 2

Our Price: $6,395.00
YSI 2700 Select Biochemistry Analyzer YSI 2700D Select Biochemistry Analyzer

YSI 2700 Select Biochemistry Analyzer Specifications

Aspirated sample volume

User selects 5 to 65 microliters

Analysis time

60 seconds

Precision

<2% cv=”n=10”

Wasteline tubing

Silicone: 0.16” OD x 0.10” ID

Nominal flow rate (inlet line)

100 to 2500 microliters per minute (+/-8% @ +/-6 PSI)

Sample Interval

2 minutes to 1,000 hours

Sample containers

10 to 16 mm diameter, 20 to 100 mm height/Volume: 5.1 microliters per inch

Sample wheel

19.1 dia. X 1.9 cm

Size

23.5 x 20.3 x 12.7 cm, 2.5 kg

Our Price: $6,995.00
Beckman Coulter ProteomeLab PA 800 System with UV Beckman Coulter ProteomeLab PA 800 System with UV

Beckman Coulter ProteomeLab PA 800 System with UV Specifications

Sampling Formats

96-well plates, microfuge tubes, PCR vials, 2ml vials

Temperature Range

20° below Ambient to 60°C (minimum setting 4°C)

Temperature Stability

±1°C

Temperature Accuracy

Temperature of environment: ±2°C within the range of ±15°C from ambient; ±3°C outside the range of ±15°C for ambient.

UV Source

Deuterium lamp; 30 W; prealigned

Wavelength Range

190 to 600 nm

Filter Selection

200, 214, 254, and 280 nm (standard); three open positions for additional wavelength selections; filter diameter 1/2 inch (127 mm); 0.20 in. thick

Wavelength Accuracy

2 nm

Analog Output

Output 1 is Data; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values).

Output 2 not used.

Output 3: Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed.

Electrical Requirements

100-240V, 50/60Hz; auto-voltage sensing power supply

Max Heat Dissipation to Room

400 W (1024 BTU/H)

Ambient Operation Temperature

15° to 40°C

Dimensions (W x H x D)

22.38 x 27.13 x 24.13 in (56.83 x 68.9 x 61.28 cm)

Laser Module Dimensions (W x H x D)

10.25 x 25 x 14.25 in (26.3 x 63.3 x 35 cm)

Our Price: $6,995.00
Beckman Coulter ProteomeLab PA 800 System with LIF Beckman Coulter ProteomeLab PA 800 System with LIF

Beckman Coulter ProteomeLab PA 800 System with LIF Specifications

Sampling Formats

96-well plates, microfuge tubes, PCR vials, 2ml vials

Temperature Range

20° below Ambient to 60°C (minimum setting 4°C)

Temperature Stability

±1°C

Temperature Accuracy

Temperature of environment: ±2°C within the range of ±15°C from ambient; ±3°C outside the range of ±15°C for ambient.

Relative Fluorescence Units Range

0 to 1000 RFU

Dynamic Range (at a dynamic range setting of 1000)

> 10^4

Sensitivity

1 x 10^-11M Sodium Fluorescein with a signal-to noise ratio ≥ 2

Baseline Noise

< 0.005 RFU peak to peak

Baseline Drift

< 0.2 RFU per hour

Filters (optional)

For user supplied lasers: Each laser configuration requires two filters, a laser filter to block stray laser light and an emission filter to select the wavelength of the emitted light. These filters must have an outside diameter of 0.500” (+.000, -.010”) and a thickness not greater than 0.350”; if multiple filters are used in a single channel, the total thickness cannot exceed 0.350”.

Fiber Cable Length

6 ft (1.83 m)

Software Requirements

32 Karat Software, Version 7.0 or later

Laser

3 mW 488 nm (air-cooled) Argon Ion Laser

Analog Outputs

Output 1 is Data Channel 1 and Output 2 is Data Channel 2; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values)

Output 3 is Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed

Electrical Requirements

100-240V, 50/60Hz; auto-voltage sensing power supply

Max Heat Dissipation to Room

400 W (1024 BTU/H)

Ambient Operation Temperature

15° to 40°C

Dimensions (W x H x D)

22.38 x 27.13 x 24.13 in (56.83 x 68.9 x 61.28 cm)

Laser Module Dimensions (W x H x D)

10.25 x 25 x 14.25 in (26.3 x 63.3 x 35 cm)

Our Price: $9,995.00