Home > Microplate Washers >

BioTek ELX405R Microplate Washer
BioTek ELX405R Microplate Washer
Click Here to View the Technical Specs for the ELx405R
 
Alternative Views:


Our Price: $3,295.00

Marshall Scientific Repeat Customer Rewards.
You'll earn 70 points towards a future purchase.

Condition: Refurbished and Tested to Manufacturer Spec
Warranty: 90-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days

Do you need a Formal Quote to help process this order? Click Here


Quantity in Stock:1
Product Code: BIO-405R
Qty:

Description Operator's Guide Marshall Scientific FAQ's
 

BioTek ELx405R Microplate Washer


The Biotek ELx405R microplate washers are both efficient and space conscious in all lab settings. The BiotekELx405R platewasher features a patented dual-action manifold to ensure fast operating time and overall cleaning efficiency. Contrary to its small size, the ELx405R plate washer series comes fully loaded with an array of preprogrammed plate washer settings to guarantee optimal performance no matter the microplate type. Among these programs, the ELx405R also employs unique AutoPrime and AutoRinse functions for both speedy maintenance and quick prep times. The ELx405R is specifically designed to handle applications using magnetic bead technology. A second carrier positions the magnet plate close to the microplate bottom, securing magnetic beads during the critical aspiration cycles.

All of our equipment is fully tested to perform at factory specifications before being shipped.


Includes: > Waste & Buffer Bottles > Vacuum Pump > Power Cord > Full 90 Day Parts and Labor Warranty.


BioTek ELx405R Microplate Washer Specifications

Microplate Types

96-well

Low profile and standard height

Deep well plates up to 50 millimeters

Onboard Software

Create, edit and run multiple protocols

Soaking

Programmable up to 60 minutes

Manifold Types

96 Tube Dual Action manifold for 96-well washing

Volume Range

50 to 3000 microliter increments

Wash Cycles

1 -10

Buffer/reagent Selection

Auto switching module for up to 4 buffers (option)

Supply bottle

4 L

Dispense Precision

≤3% CV: 300 µL/well (96-well washing)

Residual Volume

<2 µL/well (standard & deep well 96-well plates)

Wash Speed

96-wells, 300 µL/well, 3 cycles: <30 seconds

Flow Rates

High flow to low flow

Optimized rates for cell assays

Sterilization

Chemical

Vacuum Filtration

Selectable: Approximate final at 30 seconds:

Lowest: -38 mmHg

Low: -113 mmHg

Medium: -200 mmHg

High: -390 mmHg

Highest: -506 mmHg

Vacuum filtration time range: 5 to 999 seconds


Biotek ELx405 Manual

Click Here to View all the Technical Specs for the ELx405R

BioTek ELx405R Microplate Washer - Marshall Scientific

BioTek ELx405 Microplate Washer

Why Buy From Marshall Scientific?

With over 3,500 university, research, and hospital labs served, Marshall Scientific boasts a 99.8% customer satisfaction rate with less than 1% instrument failure in the field.

Our A+ Better Business Bureau rating confirms our business integrity. Marshall Scientific promises to be transparent, honest, and responsive throughout the purchase process.

By outfitting your lab with Marshall Scientific, you can save up to 70% with our refurbished instrument inventory - all guaranteed to work and under our full parts and labor warranty.

Marshall Scientific is not an equipment broker or an auction company. All of our products are evaluated and refurbished by our trained technicians.

Unlike other used or refurbished sellers, Marshall Scientific offers completely transparent product stock and pricing. You can easily see what we have and how much it costs.

All of Marshall Scientific’s products are carefully packaged, crated, and insured to protect your equipment and will be ready for immediate use in your lab.

Rest assured, our devoted technical and customer service team is with you before, during, and after your purchase to insure everything works the way it should.

Full 90-Day Parts & Labor Protection

Marshall Scientific's Refurbishment Protocol

×

Our technicians decontaminate and clean all equipment upon arrival and upon purchase to create a neutral environment for lab use.

Preliminary testing is conducted to identify potential product defects. Upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction from excessive use are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your instrument performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Microplate Washers