Home > Electrophoresis >

Beckman Coulter ProteomeLab PA 800 System with UV
Beckman Coulter ProteomeLab PA 800 System with UV
 
Alternative Views:


Our Price: $6,995.00

Condition: Fully Refurbished and Tested to Manufacturer Specifications
Warranty: 90-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 4 to 8 Business Days

Request a Formal Quote


Quantity in Stock:1
Product Code: BCP800
Qty:

Description
Refurbishment Protocol
 

Beckman Coulter ProteomeLab PA 800 System with UV


The Beckman Coulter ProteomeLab PA 800 System with UV resolves and quantifies proteins by their isoelectric point and molecular weight, generates high-resolution peptide maps and carbohydrate profiles, and provides front-end separation to mass spectrometry. Beckman Coulter's expertise in capillary electrophoresis and automation technologies ensures comprehensive in-solution protein characterization for optimal proteomics discovery in the ProtemoeLab PA 800. This system employs the proteomic process of identification, isolation, fractionation, characterization, evaluation, and diagnosis for the best possible results within your research.

The PA 800 allows identification via flow cytometry, automated fuorescence microscopy, microarray technology, and cell viability analysis; isolation via general purpose and high performance centrifugation, ultracentrifugation, centrifugal elutriation, and automated liquid handling; fractionation via high performance centrifugation, ultracentrifugation, and liquid chromatography; characterization via capillary electrophoresis/mass spectrometry, spectrophotometry, protein characterization in solution, and automated protein crystallization; evaluation via microarray technology and software solutions; and diagnosis via automated immunoassay, flow cytometry, electrophoresis, immunochemistry, and immunofixation.


The ProteomeLab PA 800 can be used for most proteomic processes, including cellular isolation, protein fractionation, subcellular fractionation, protein characterization, antigen identification, data evaluation, and disease diagnosis.

All of our equipment is fully tested to perform at factory specifications before being shipped.

Included with the Beckman Coulter ProteomeLab PA 800 System with UV:
Includes: > Data Station with Preloaded Software > Calibration Report > Power Cord > Full 90 Day Parts and Labor Warranty

Beckman Coulter ProteomeLab PA 800 System with UV Specifications

Sampling Formats

96-well plates, microfuge tubes, PCR vials, 2ml vials

Temperature Range

20° below Ambient to 60°C (minimum setting 4°C)

Temperature Stability

±1°C

Temperature Accuracy

Temperature of environment: ±2°C within the range of ±15°C from ambient; ±3°C outside the range of ±15°C for ambient.

UV Source

Deuterium lamp; 30 W; prealigned

Wavelength Range

190 to 600 nm

Filter Selection

200, 214, 254, and 280 nm (standard); three open positions for additional wavelength selections; filter diameter 1/2 inch (127 mm); 0.20 in. thick

Wavelength Accuracy

2 nm

Analog Output

Output 1 is Data; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values).

Output 2 not used.

Output 3: Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed.

Electrical Requirements

100-240V, 50/60Hz; auto-voltage sensing power supply

Max Heat Dissipation to Room

400 W (1024 BTU/H)

Ambient Operation Temperature

15° to 40°C

Dimensions (W x H x D)

22.38 x 27.13 x 24.13 in (56.83 x 68.9 x 61.28 cm)

Laser Module Dimensions (W x H x D)

10.25 x 25 x 14.25 in (26.3 x 63.3 x 35 cm)


Why Buy From Marshall Scientific?

Every product we offer undergoes a rigorous inspection process to verify that all manufacturer specifications are met. All of the electronics and boards are tested for proper function, and any necessary preventative maintenance is performed alongside repairs by our industry trained technicians. Our primary goal is to offer products that are as close to new as possible at an affordable price.

All Lab Equipment is Fully Refurbished and Tested

Most Pieces Ship within 2 to 5 Business Days

All Products Come with a Standard Warranty

Trained Customer and Technical Support

Industry Leading Overall Customer Satisfaction

Marshall Scientific's Certified Refurbishment Protocol

×

Our technicians decontaminate and clean all equipment upon arrival and upon purchase to create a neutral environment for lab use.

Preliminary testing is conducted to identify potential product defects, upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction from excessive use are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your instrument performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.

Once we finish our rigorous testing and decontamination procedures, your order will be packaged to best protect it during shipment and will include delivery insurance.


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Electrophoresis
Analyzers > Electrophoresis Analyzers
Analyzers