Beckman Coulter Allegra X-30R Refrigerated Centrifuge
Maximum Speed 18,000 RPM (10,000 RPM with included rotor)
Temperature Range -20C to 40C
Maximum Capacity 4 x 400ml
- Compact benchtop design saves space while supporting a wide range of research and clinical applications
- Microprocessor-controlled interface with interactive operation and intuitive setup
- Brushless three-phase drive system ensures quiet, maintenance-free performance
- Automatic rotor overspeed identification for enhanced operational safety
- Electromechanical door-locking mechanism prevents access while the rotor is in motion
- Steel barrier around rotor chamber provides full operator protection during operation
- Imbalance detection system automatically shuts down the unit in case of uneven loads
- Cleared for In Vitro Diagnostic (IVD) use
- Compatible with a wide selection of rotors and adapters for flexible laboratory use
The Beckman Coulter Allegra X-30R Refrigerated Centrifuge, FDA-cleared for In Vitro Diagnostic (IVD) use, is designed for versatility, meeting the needs of labs conducting general research or clinical sample preparation. With a wide range of compatible rotors combined with simple user control of acceleration and deceleration rates, this centrifuge is capable of use in a number of applications including extractions, concentrations, phase separations and pelleting. With the ability to cool from room temperature to 4°C in ten minutes, the Beckman Coulter Allegra X-30R Refrigerated Centrifuge is an impeccable option for laboratories that require a responsive and adaptable option for varying sample types.
Engineered for safety and efficiency, the Allegra X-30R's imbalance detection, and rotor overspeed identification ensure samples are safe and secure throughout processing. The electromechanical door lock mechanism also prevents operator contact with spinning rotors. When closed, the door locks automatically, and can only be unlocked by the user when the power is on and the rotor is at rest. The X-30R is equipped with two separate monitoring systems which prevent door opening while the rotor is spinning. With micro-processor control providing simple user interaction along with a brushless three-phase drive system ensuring quiet and clean operation, the Beckman Coulter Allegra X-30R is tailored for the changing needs of researchers throughout their sample preparation processes. The included C0650 6 x 50ml Fixed Angle Rotor reaches a maximum speed of 10,000 RPM and a maximum RCF of 10,304 x g. This centrifuge is suitable for validated IVD applications and laboratory use.All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Beckman Coulter Allegra X-30R Refrigerated Centrifuge includes:
- > C0650 6 x 50ml Fixed Angle Rotor
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Beckman Coulter Allegra X-30R Refrigerated Centrifuge Specifications
|
Maximum Speed
|
18,000 RPM (10,000 RPM with included rotor)
|
|
Maximum RCF
|
29,756 x g (10,304 x g with included rotor)
|
|
Speed Increments
|
100 RPM
|
|
Speed Accuracy
|
± 50 RPM of set speed
|
|
Maximum Capacity
|
4 x 400ml
|
|
Temperature Range
|
-20C to 40C
|
|
Timer
|
1 minute to 9 hours 59 minutes or continuous run (hold) mode
|
|
Acceleration Rates
|
10
|
|
Deceleration Rates
|
10
|
|
Noise Level
|
≤ 68 dBa
|
|
Maximum Heat Dissipation
|
3311 Btu/h (0.97 kW)
|
|
Dimensions (W x D x H)
|
18.1 x 27.8 x 14.6 in. (46 x 70.7 x 37 cm)
|
|
Weight
|
172 lb. (78 kg)
|
|
Electrical Requirements
|
120V, 60Hz, 11.5A
|
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
| Task |
Completed? |
Remarks? |
| Confirm power supply output voltages match specified requirements |
Completed |
|
| Measure and verify voltages at PCB test points for accuracy |
Completed |
|
| Confirm rotor compatibility and detection for proper identification |
Completed |
|
| Inspect exterior for cosmetic or structural damage |
Completed |
|
| Check door mechanism alignment for secure opening and closing |
Completed |
|
| Inspect and replace gas strut with OEM part as needed |
Completed |
|
| Examine rotor chamber for dents or damage and replace if necessary |
Completed |
|
| Replace and confirm functionality of all lid lock switches |
Completed |
|
| Lubricate door lock mechanism and lid lock rail for smooth operation |
Completed |
|
| Test compressor (if applicable) for proper operation and cooling |
Completed |
|
| Run 8-12 hour cycle test to ensure consistent performance |
Completed |
|
| Check rotor motor for stability, noise, and integrity |
Completed |
|
| Inspect and clear condensation drain to prevent buildup |
Completed |
|
| Verify RPM accuracy with NIST traceable tachometer and calibrate |
Completed |
|
| Check centrifuge error log for zero recorded issues |
Completed |
|
To View More of Our Recertification Protocol Click Here
|
|
 |
 |
 |
 |

|