Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System
Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System
 
 



Our Price: $70,995.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 2 to 3 Weeks
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report & Mass Spec Tuning Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-6120BMS1200
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System



Mass Range
2 to 2,000 m/z

Mass Accuracy
± 0.13 Da

Scan Speed
10,400 Da/sec

Features
  • Features 300 msec ion polarity switching for maximum data collection
  • Supports multiple ionization sources including ESI, APCI, APPI, and multimode options
  • Provides dynamic range exceeding 6 × 10⁶ for reliable quantitation
  • Ensures long-term stability with < 0.1 amu mass drift over 12 hours
  • High-performance detector with high gain electron multiplier horn
  • Fully controlled via Agilent ChemStation Workstation Software for streamlined operation
  • SIM sensitivity with signal-to-noise ratio > 75:1 for ESI positive mode
  • Maximum SIM dwell time of 5 msec for fast, accurate quantitation
  • Equipped with a reliable vacuum system featuring a turbo-molecular and mechanical pump

The Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6120B model is specifically a flexible, high performance solution ideal for any quantitation application with a 2 to 2,000 m/z mass range and 1 pg sensitivity. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System provides unmatched sensitivity, simplifying sample preparation. An ultrafast scan speed allows users to take full advantage of LC separations when paired with an Agilent LC System, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. The Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.

This Agilent LC/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System includes:
  • > Agilent 6120B Single Quadrupole Mass Spectrometer
  • > Agilent MS40+ Rotary Vane Vacuum Pump
  • > G1948B ESI Ionization Source
  • > G1312B Binary Pump (G1311A Quaternary Pump available, please inquire)
  • > G1329A Autosampler
  • > G1330B ALS Thermostat
  • > G1316A TCC
  • > G1379B Degasser
  • > G1315C DAD Detector
  • > Windows 11 Professional 64-Bit Data Station with Flatscreen Monitor
  • > ChemStation Version 4.3 Software Installed
  • > All Power Cords
  • > Can/Crossover Cables
  • > Agilent Lan Interface Card Built-In
  • > Solvent Tubing
  • > Capillaries
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report & Mass Spec Tuning Report
  • > Full 180 Day Parts and Labor Warranty



Below is a List of Diagnostic Tests Performed On This LC System
G1315C Diode Array Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G1312B Binary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G1316A Column Compartment Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G1329A Autosampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 LC System.


Agilent 6120B Single Quadrupole Mass Spectrometer w/ 1200 LC System Specifications

Maximum Scan Speed 10,400 Da/sec
SIM Sensitivity, ESI Positive Signal-to-noise ratio > 75:1 (1 pg of reserpine injected on column,
quantifying the m/z 609 ion)
SIM Sensitivity, APCI Positive Signal-to-noise ratio > 10:1 (1 pg of reserpine injected on column,
quantifying the m/z 609 ion)
Polarity Switching 300 msec (switching time from positive to negative polarity)
Mass Resolution (Autotune) Unit resolution (full width at half maximum)
Mass Stability < 0.1 amu or 100 ppm, whichever is larger (over 12 hours)
Mass Accuracy ± 0.13 Da
Maximum SIM Dwell Time 5 msec
Maximum SIM Transitions

100 (one time segment)

Dynamic Range > 6 × 10 6
Mass Range 2 to 2,000 m/z
Single Point of Control Single-point data system method capability with full control of Agilent 1200 Series LC Systems and 6100 Series Single Quadrupole LC/MS Systems
Time Programming SIM ion selections, Scan functions, Fragmentor voltage, External CAN valves
Ionization Sources Electrospray (ESI), Multimode source (simultaneous ESI and APCI), Atmospheric pressure chemical ionization (APCI), ChipCube for intergrated nanoLC, Atmospheric pressure photoionization (APPI)
Detector High energy conversion dynode and high gain electron multiplier horn
Vacuum System One turbo-molecular pump with one mechanical pump
Dimensions (W x H x D) 14 x 18 x 25 in. (35 x 45 x 63.5 cm)
Weight 137.6 lb. (63.4 kg.)
Electrical Requirements 200-230VAC, 60Hz or 200-240VAC, 50Hz

Click Here to View Specifications for the Agilent 1200 LC System

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 950 nm
Short Term Noise (ASTM) Single and Multi-Wavelength ± 0.8 × 10 -5 AU at 254 and 750 nm
Drift 0.9 × 10 -3 AU/hr at 254 nm
Linear Absorbance Range > 2.0 AU (upper limit)
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 1, 2, 4, 8, 16 nm
Diode Width < 1 nm
Flow Cells

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Binary Pump Specification
Hydraulic System Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
Setable Flow Range 0.001 – 5 ml/min, in 0.001 ml/min increments
Flow Range

0.1 - 5.0 mL/min

Flow Precision ≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater
Flow Accuracy ± 1% or 10 µl/min, what ever is greater
Pressure Operating Range Operating range 0 to 600 bar (0 – 7800 psi) up to 5 ml/min
Pressure Pulsation < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
Compressibility Compensation User-selectable, based on mobile phase compressibility
Recommended pH Range 1.0 - 12.5
Gradient Formation High-pressure binary mixing
Delay Volume 600 to 800 µl, dependent on back pressure
Composition Range 0 to 100% (1 to 99% or 5 µl/min per channel, whatever is greater is recommended)
Composition Precision < 0.15% RSD
Composition Accuracy ± 0.35% absolute
Autosampler Specification
Injection Range 0.1 - 100 µl in 0.1 µl increments
Precision

< 0.25 % RSD of peak areas from 5 to 100 µl

< 1 % RSD of peak areas from 1 to 5 µl

Pressure Range Operating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)
Sample Viscosity Range 0.2 to 50 cp
Sample Capacity 100 × 2 mL vials in 1 tray
40 × 2 mL vials in ½ tray
15 × 6 mL vials in ½ tray (Agilent vials only)
Injection Cycle Time 50 s for draw speed 200 µL/min, ejection speed 200 µL/min, injection volume 5 µL
Carryover Typically < 0.1 %, < 0.05 % with external needle cleaning
ALS Thermostat Specification
Temperature Range 4°C to 40°C in 1°C increments
Temperature Accuracy at Ambient Temperatures < 25°C and Humidity < 50% -1°C to +4°C at a setpoint of 4°C
Temperature Accuracy at Ambient Temperatures > 25°C and Humidity > 50% -1°C to +5°C at a setpoint of 4°C
Column Compartment Specification
Temperature Range Ambient -10°C to 80°C at flow rates up to 5 mL/min
Temperature Stability ± 0.15 °C
Temperature Accuracy ± 0.8°C (± 0.5°C with calibration)
Column Capacity Three 30 cm
Warm-Up/Cool-Down Time 5 minutes from ambient to 40°C
10 minutes from 40°C to 20°C
Dead Volume

3 µl left heat exchanger

6 µl right heat exchanger

Degasser Specification
Number of Solvent Channels 4
Maximum Flow Rate 0 - 10 mL/min per channel
Internal Volume Per Channel Typically 12 ml per channel
Materials in Contact with Solvent PTFE, PEEK
pH Range 1 - 14


Computer Specifications

Processor Intel Core I5-8500 CPU
RAM 32.0 GB
Hard Drive 500GB Internal SSD
Operating System Windows 11 Professional, 64-bit
Downloads