Home > Chromatography - HPLC >

Agilent 1260 Infinity I HPLC System w/ DAD
Agilent 1260 Infinity I HPLC System w/ DAD
 
 



Our Price: $53,995.00
Sale Price: $41,995.00
Money Saved: $12,000.00

Price with Selected Options: $41,995.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-1260HPLCDAD

Please Select an Option Below

Select Additional Detector*:


Qty:
Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1260 Infinity I HPLC System w/ DAD



Wavelength Range (DAD)
190 to 640 nm

Pressure Range (FLD)
0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)

Flow Rate Range
0.001 to 10 ml/min

Features
  • Offers flexibility for solvent selection and automation in HPLC method development and high-throughput workflows
  • Features a vacuum degasser integrated into the pump for efficient degassing of solvents
  • Quaternary pump accommodates a wide range of solvent compatibilities and mixing capabilities for diverse HPLC applications
  • Autosampler designed with a flow-through needle for low carryover and high-speed sample processing
  • Programmable slit widths in DAD allow for rapid optimization of detection sensitivity and spectral resolution
  • ALS thermostat manages temperature from 4°C to 40°C, ensuring optimal conditions for sensitive analyses
  • Column compartment maintains temperature with high stability and accuracy, facilitating reproducible results
  • Includes Agilent ChemStation Workstation Software for comprehensive control over data acquisition and analysis
  • Enables rapid method development with convenient access to four solvents for isocratic or gradient analysis

The Agilent 1260 Infinity I HPLC System w/ DAD offers the most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring continuous access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers convenient access to four solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system.

The Agilent 1260 Infinity HPLC System's quaternary pump is based on a two-channel, dual-plunger in-series design which comprises all essential functions that a solvent delivery system has to fulfill. Metering of solvent and delivery to the high-pressure side are performed by one pump assembly which can generate pressure up to 600 bar. Degassing of the solvents is done in a built-in vacuum degasser integrated into the quaternary pump. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume injection and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and precision. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of retention time reproducibility. The featured Diode-Array Detector (DAD) is designed for the highest optical performance, GLP compliance, and easy maintenance. The DAD provides greatly enhanced sensitivity and baseline stability using a cartridge cell system with optofluidic waveguides. This detector provides for a wavelength range of 190 - 950 nm, a data acquisition rate of up to 80 Hz, and a programmable 1, 2, 4, 8, or 16 nm slit for rapid optimization of sensitivity, linearity, and spectral resolution.

The Agilent 1260 Infinity HPLC System w/ DAD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.


This Agilent system is in excellent condition and will be fully tested to perform at factory specifications before being shipped.


INCLUDED:
The Agilent 1260 Infinity I HPLC System w/ DAD includes:
  • > G1311B Quaternary Pump (With Built-In Degasser)
  • > G1329B Autosampler
  • > G1330B ALS Thermostat
  • > G1316C TCC
  • > G4212B DAD Detector
  • > Windows 11 Professional 64-Bit Data Station with Flatscreen Monitor
  • > ChemStation Version 4.3 Software Installed
  • > Can/Crossover Cables
  • > Agilent Lan Interface Card Built-In
  • > Solvent Tubing
  • > 4 x Bottles, Caps and Solvent Filters
  • > New Stainless Steel Capillaries
  • > 1/4" Wrench & Mobile Phase Priming Syringe
  • > Waste Tubing
  • > All Power Cords
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
  • > Full 180 Day Parts and Labor Warranty



Below is a List of Diagnostic Tests Performed On This System
G4212B Diode Array Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G1311B Quaternary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G1316C Column Compartment Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G1329B Autosampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.


Agilent 1260 Infinity I HPLC System w/ DAD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 × 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 × 10^-3 AU/hr at 254 nm
Linear Absorbance Range
> 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cell

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC
Analog Outputs

Recorder/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN

Safety and Maintenance

Extensive diagnostics, error detection, and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP Features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

Housing All materials recyclable

Click Here to View More Specifications for the Agilent 1260 Infinity HPLC System

Quaternary Pump Specification
Setable Flow Range 0.001 - 10 mL/min, in 0.001 mL/min increments
Flow Range

0.05 - 10.0 mL/min

Flow Precision < 0.07% RSD or < 0.02 min SD, whatever is greater based on retention time at constant ambient temperature
Flow Accuracy ± 1% or 10 µl/min
Pressure Operating Range 0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL/min, 0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 mL/min
Pressure Pulsation < 2% amplitude or < 3 bar at 1 mL/min isopropanol, at all pressures > 1 MPa (10 bar, 147 psi)
Composition Range Settable range: 0 - 95% or 5 - 100%
Composition Precision < 0.2 % RSD or < 0.04 min SD
Delay Volume 600 - 900 µl, dependent on back pressure
Autosampler Specification
Injection Range 0.1 - 100 µl in 0.1 µl increments (recommended 1 µl increments)
Precision Typically < 0.25 % RSD of peak areas from 5 - 100 µl, Typically < 1 % RSD of peak areas from 1 - 5 µl
Pressure Range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)
Sample Viscosity Range 0.2 - 50 cp
Sample Capacity

100 × 2 mL vials in 1 tray

40 × 2 mL vials in ½ tray

15 × 6 mL vials in ½ tray (Agilent vials only)

Injection Cycle Time 50 s for draw speed 200 µL/min, ejection speed 200 µl/min, injection volume 5 µl
Carryover Typically < 0.1 %, < 0.05 % with external needle cleaning
ALS Thermostat Specification
Temperature Range 4°C to 40°C in 1°C increments
Temperature Accuracy at Ambient Temperatures < 25°C and Humidity < 50% 3°C to 8°C at a setpoint of 4°C
Temperature Accuracy at Ambient Temperatures > 30°C and Humidity > 60% 3°C to 9°C at a setpoint of 4°C
Column Compartment Specification
Temperature Range Ambient -10°C to 80°C at flow rates up to 5 mL/min
Temperature Stability ± 0.15°C
Temperature Accuracy ± 0.8°C
Warm-Up/Cool-Down Time 5 minutes from ambient to 40°C
10 minutes from 40°C to 20°C


Computer Specifications

Processor Intel Core I5-8500 CPU
RAM 32.0 GB
Hard Drive 500GB Internal SSD
Operating System Windows 11 Professional, 64-bit
Downloads


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Chromatography - HPLC
Brand
Brand > Agilent
Chromatography Component
Chromatography Component > Systems