Agilent 1260 Infinity I HPLC System w/ DAD
The Agilent 1260 Infinity I HPLC System w/ DAD offers
the most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring continuous access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers convenient access to four solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system.
The Agilent 1260 Infinity HPLC System's quaternary pump is based on a two-channel, dual-plunger in-series design which comprises all essential functions that a solvent delivery system has to fulfill. Metering of solvent and delivery to the high-pressure side are performed by one pump assembly which can generate pressure up to 600 bar. Degassing of the solvents is done in a built-in vacuum degasser integrated into the quaternary pump. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume injection and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and precision. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of retention time reproducibility. The featured Diode-Array Detector (DAD) is designed for the highest optical performance, GLP compliance, and easy maintenance. The DAD provides greatly enhanced sensitivity and baseline stability using a cartridge cell system with optofluidic waveguides. This detector provides for a wavelength range of 190 - 950 nm, a data acquisition rate of up to 80 Hz, and a programmable 1, 2, 4, 8, or 16 nm slit for rapid optimization of sensitivity, linearity, and spectral resolution.
The Agilent 1260 Infinity HPLC System w/ DAD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.
This Agilent system is in excellent condition and will be fully tested to perform at factory
specifications before being shipped.
The Agilent 1260 Infinity I HPLC System w/ DAD includes:
- > G1311B Quaternary Pump (With Built-In Degasser)
- > G1329B Autosampler
- > G1330B ALS Thermostat
- > G1316C TCC
- > G1315D DAD Detector
- > Windows 10 Professional 64-Bit Data Station with Flatscreen Monitor
- > ChemStation Version 4.3 Software Installed
- > Can/Crossover Cables
- > Agilent Lan Interface Card Built-In
- > Solvent Tubing
- > 4 x Bottles, Caps and Solvent Filters
- > New Stainless Steel Capillaries
- > 1/4" Wrench & Mobile Phase Priming Syringe
- > Waste Tubing
- > All Power Cords
- > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
- > Full 180 Day Parts and Labor Warranty
Below is a List of Diagnostic Tests Performed On This System
- Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
- Dark Current Test: The test measures the dark current from the detector optic.
- Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
- Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
- Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
- Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
- Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
- Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
- Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
- Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
- 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.
Agilent 1260 Infinity I HPLC System w/ DAD Specifications
DAD Detector
|
Specification
|
Detection Type
|
1024-element photodiode array
|
Light Source
|
Deuterium and tungsten lamps
|
Wavelength Range
|
190 - 950 nm
|
Short Term Noise (ASTM) Single and Multi-Wavelength
|
< ± 0.7 × 10^-5 AU at 254 nm and 750 nm
|
Drift
|
< 0.9 × 10^-3 AU/hr at 254 nm
|
Linear Absorbance Range
|
> 2.0 AU (5%) at 265 nm
|
Wavelength Accuracy
|
± 1 nm
|
Wavelength Bunching
|
1 - 400 nm
|
Slit Width
|
1, 2, 4, 8, 16 nm / programmable slit
|
Diode Width
|
< 1 nm
|
Signal Data Rate
|
Up to 80 Hz
|
Spectra Data Rate
|
Up to 80 Hz
|
Flow Cell
|
Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum
|
Control and Data Evaluation
|
Agilent ChemStation for LC
|
Analog Outputs
|
Recorder/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output
|
Communications
|
Controller-area network (CAN), GPIB,
RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN
|
Safety and Maintenance
|
Extensive diagnostics, error detection, and display (through control module
and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
|
GLP Features
|
Early maintenance feedback (EMF) for continuous tracking of instrument
usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.
|
Housing
|
All materials recyclable
|
Click Here to View More Specifications for the Agilent 1260 Infinity HPLC System
Quaternary Pump
|
Specification
|
Setable Flow Range
|
0.001 - 10 mL/min, in 0.001 mL/min increments
|
Flow Range
|
0.05 - 10.0 mL/min
|
Flow Precision
|
< 0.07% RSD or < 0.02 min SD, whatever is greater based on retention time at constant ambient temperature
|
Flow Accuracy
|
± 1% or 10 µl/min
|
Pressure Operating Range
|
0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL/min, 0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 mL/min
|
Pressure Pulsation
|
< 2% amplitude or < 3 bar at 1 mL/min isopropanol, at all pressures > 1 MPa (10 bar, 147 psi)
|
Composition Range
|
Settable range: 0 - 95% or 5 - 100%
|
Composition Precision
|
< 0.2 % RSD or < 0.04 min SD
|
Delay Volume
|
600 - 900 µl, dependent on back pressure
|
Autosampler
|
Specification
|
Injection Range
|
0.1 - 100 µl in 0.1 µl increments (recommended 1 µl increments)
|
Precision
|
Typically < 0.25 % RSD of peak areas from 5 - 100 µl, Typically < 1 % RSD of peak areas from 1 - 5 µl
|
Pressure Range
|
0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)
|
Sample Viscosity Range
|
0.2 - 50 cp
|
Sample Capacity
|
100 × 2 mL vials in 1 tray
40 × 2 mL vials in ½ tray
15 × 6 mL vials in ½ tray (Agilent vials only)
|
Injection Cycle Time
|
50 s for draw speed 200 µL/min, ejection speed 200 µl/min, injection volume 5 µl
|
Carryover
|
Typically < 0.1 %, < 0.05 % with external needle cleaning
|
ALS Thermostat
|
Specification
|
Temperature Range
|
4°C to 40°C in 1°C increments
|
Temperature Accuracy at Ambient Temperatures < 25°C and Humidity < 50%
|
3°C to 8°C at a setpoint of 4°C
|
Temperature Accuracy at Ambient Temperatures > 30°C and Humidity > 60%
|
3°C to 9°C at a setpoint of 4°C
|
Column Compartment
|
Specification
|
Temperature Range
|
Ambient -10°C to 80°C at flow rates up to 5 mL/min
|
Temperature Stability
|
± 0.15°C
|
Temperature Accuracy
|
± 0.8°C
|
Warm-Up/Cool-Down Time
|
5 minutes from ambient to 40°C
10 minutes from 40°C to 20°C
|
Computer Specifications
|
Model
|
Dell Optiplex 7010 Desktop PC
|
Processor
|
Intel Core i5-3470 Processor 3.2GHz
|
Ram
|
16GB
|
Hard Drive
|
250GB Internal SSD
|
Operating System
|
Windows 10 Professional, 64bit
|
- Confirm Main and Residential Firmware of All Components Is Uniform - Update If Required.
- Confirm Software Is Successfully Communicating with The Hplc System
- Confirm Degasser’s Internal Vacuum Is Pulling to Acceptable Vacuum Level
- Replace Inlet, Outlet, Purge Valve and Pump Seals of System Pump
- Confirm System Pump Passes Both Pressure Test and Leak Test
- Replace All Capillary Tubing with New Oem Stainless Steel Tubing
- Remove Autosampler Transport Assembly and Replace X And Y Bearings/Clean Carrier Rails of All Debris/Contaminants
- Replace Metering Valve Seal, Autosampler Needle, And Autosampler Needle Seat
- Confirm Column Compartment Switching Valve Functionality and Replace Seal
- Confirm Column Compartment Passes Thermostat Test
- Remove And Clean Internal Detector Optics
- Replace Uv and Vis Detector Lamps
- Confirm Flow Cell Absorbance Is Performing Within Manufacturer’s Specifications
- Confirm System Is Properly Responding to Isocratic Test Sample
To View More of Our Recertification Protocol Click Here
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Every product we offer undergoes a rigorous inspection process to verify that all manufacturer specifications are met. All of the electronics and boards are tested for proper function, and any necessary preventative maintenance is performed alongside repairs by our industry trained technicians. Our primary goal is to offer products that are as close to new as possible at an affordable price.
All Lab Equipment is Fully Recertified and Tested
Most Pieces Ship within 2 to 5 Business Days
All Products are Fully Warrantied
Trained Customer and Technical Support
Industry Leading Overall Customer Satisfaction
Working with Marshall Scientific was overall an enjoyable experience. Their customer service really helped me choose the product that fit my needs, and checking out was easier than I expected. Shipping was faster than expected which was also a plus!
James M. / Bausch + Lomb
I have purchased a few items from Marshall Scientific over the years and I have always had great experiences with both the products and the customer support. Chat feature definitely makes both communicating and navigating easier. I would recommend this company to a colleague.
Lila B. / Caltech
I just received the two Polyscience chillers I ordered through your ecommerce store and I couldn't be happier with my purchase. Customer service was instrumental in helping me choose the correct model. Thanks again!
Nora F. / Sanofi
Working with Marshall Scientific has been an exceptional experience. Their team assisted me in selecting the perfect recirculating chiller for my research needs. Their expertise and guidance were invaluable, and I am grateful for their support. Marshall Scientific has been vital to the success of my research endeavors.
Zara K. / Ford
Collaborating with Marshall Scientific has been a truly exceptional experience. Their fast lead time for centrifuges is unparalleled, and their commitment to quality is evident in every aspect of their service. I would highly recommend them to anyone in need of a reliable and efficient scientific equipment supplier.
Mei L. / AWS
I recently ordered pipettes from Marshall Scientific and was impressed with their great selection and quality. The pipettes were exactly what I needed and worked perfectly. I would definitely order from them again.
Aarav S. / Pfizer
The chat support I received while selecting a thermal cycler was exceptional. The representative was knowledgeable, patient, and helped me choose the perfect product for my needs. I am grateful for their assistance.
Anneliese M. / Mayo Clinic
I recently purchased a ChemiDoc imaging system from Marshall Scientific and was impressed with the great condition it arrived in. The shipping was professional and the system has been a valuable addition to my scientific research.
Tyler S. / University of Pennsylvania
The New Brunswick Incubator Shaker that I ordered from Marshall Scientific has just arrived and I cannot say enough how satisfied I am with my purchase. The shaker works like it came straight from the factory and the longer warranty is definitely a plus. I highly recommend Marshall to anyone looking for a company that stands behind their products.
Xiao L. / MIT
My recently purchased microplate reader from Marshall Scientific has been a much needed addition to my lab. The reader is easy to use and provides accurate and reliable results. I have used it for various experiments including ELISA, cell viability assays, and protein quantification. The reader has greatly improved the efficiency and accuracy of my experiments. Thanks again!
Larisa R. / MGH
I purchased a recirculating chiller from Marshall Scientific three months ago and couldn't be happier. The Thermoflex 2500 is a great unit and has been working perfectly. I actually bought three of them and they have exceeded my expectations.
Gavril K. / Tesla
I recently purchased a laboratory freezer from Marshall Scientific and I am very pleased with my purchase. The freezer is of high quality and has been perfect for storing my research samples. I use it mostly for cell culture and protein storage and it seems to do the job just fine. The overall cosmetic condition of the unit is perfect.
Juan M. / Columbia University
I would like to extend a thanks to Kyle on the other side of Marshall Scientific's chat feature to help me select the right product for my laboratory needs. Kyle was knowledgeable and helped me choose the perfect equipment for my application. The chat feature was convenient and saved me time. I would definitely use it again in the future.
Yumi S. / Rivian
I recently received a Vicell cell counter from Marshall Scientific and I must say, I was anxious about making such a large purchase over the internet. However, the product arrived in perfect condition and has exceeded my expectations. I use it for various applications in my lab and it has been incredibly accurate and efficient. The professional shipping was also a plus. I will definitely be purchasing from Marshall Scientific again in the future.
Ethan S. / Quest Diagnostics
Click Here to View Our Other Testimonials
|
|
 |
 |
 |
 |

|