Home > Electrophoresis >

Beckman P/ACE MDQ Capillary Electrophoresis System, UV
Beckman P/ACE MDQ Capillary Electrophoresis, UV
Click Here to View the Technical Specs for the Beckman P/ACE MDQ
 
Alternative Views:


Our Price: $8,495.00

Marshall Scientific Repeat Customer Rewards.
You'll earn 140 points towards a future purchase.

Condition: Refurbished and Tested to Manufacturer Spec
Warranty: 90-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 5 to 7 Business Days



Quantity in Stock:2
Product Code: BE-PACEUV
Qty:

Description Operator's Guide Marshall Scientific FAQ's
 

Beckman P/ACE MDQ Capillary Electrophoresis System


The Beckman P/ACE MDQ Capillary Electrophoresis System is configured with a selectable-wavelength UV/Vis detector, UV source optics, temperature-controlled sample storage module, and 32 Karat Software configured on an desktop controller. The P/ACE MDQ system offers automated multi-format sample introduction directly from 96 well plates, 2 mL autosampler vials, PCR vials, and 0.5 mL tubes. An array of 36 buffer pairs independent from the samples allows your methods development strategies to be automated while maintaining system sample capacity. The P/ACE MDQ electrophoresis system offers multiple modes of separation, including voltage, current, power, pressure, and vacuum, allowing the programming of both step and linear gradients along with the simultaneous application of pressure or vacuum on both ends of the capillary. This system features a modular high sensitivity selectable wavelength UV detector, which utilizes up to seven filters in an assembly which allows wavelength changes during a run. Sample temperature control within the P/ACE MDQ system works to minimize the degradation of temperature-labile compounds and controlling reaction rates when looking at enzyme kinetics.

All of our equipment is fully tested to perform at factory specifications before being shipped.

Includes: > Data Station with Preloaded Software > UV Detector > Capillary Cartridge > Front 48 Well Plates > Back 96 Well Plates > Calibration Report > Power Cord > Full 90 Day Parts and Labor Warranty

Beckman P/ACE MDQ Capillary Electrophoresis Specifications

Wavelength range

UV/Vis: 200, 214, 254, 280 nm
Custom filter option: 190-600 nm

Optional detectors

Diode Array or Laser Induced Fluorescence (LIF)

Sample introduction

Pressure, Vacuum, Electrokinetic

Sample temperature

5° C - 60° C

Pressure range

-5 - 100 psi (rinse/seperations), -5 - 25 psi (sample introduction)

Capillary cartridge

Recirculating liquid coolant 15°C - 60°C

Data rate collection

0.5 - 32 Hz

Sample tray

61 x 96 well plates, 2 x 48 (2mL vials), 2 x 48 (0.5mL vials), or 2 x 48 (PCR vials)

Modes of operation

Constant/Gradient voltage, current & power, variable pressure

Power requirements

115V 50/60Hz

Width

22.38 inches

Depth

24.13 inches

Height

27.13 inches / with door open 36.5 inches

Weight

132lbs + Computer


Operator's Manual

Laser Induced Flourescence (LIF) Option


Click Here to View all the Technical Specs for the Beckman P/ACE MDQ

Why Buy From Marshall Scientific?

With over 3,500 university, research, and hospital labs served, Marshall Scientific boasts a 99.8% customer satisfaction rate with less than 1% instrument failure in the field.

Our A+ Better Business Bureau rating confirms our business integrity. Marshall Scientific promises to be transparent, honest, and responsive throughout the purchase process.

By outfitting your lab with Marshall Scientific, you can save up to 70% with our refurbished instrument inventory - all guaranteed to work and under our full parts and labor warranty.

Marshall Scientific is not an equipment broker or an auction company. All of our products are evaluated and refurbished by our trained technicians.

Unlike other used or refurbished sellers, Marshall Scientific offers completely transparent product stock and pricing. You can easily see what we have and how much it costs.

All of Marshall Scientific’s products are carefully packaged, crated, and insured to protect your equipment and will be ready for immediate use in your lab.

Rest assured, our devoted technical and customer service team is with you before, during, and after your purchase to insure everything works the way it should.

Full 90-Day Parts & Labor Protection

Marshall Scientific's Refurbishment Protocol

×

Our technicians decontaminate and clean all equipment upon arrival and upon purchase to create a neutral environment for lab use.

Preliminary testing is conducted to identify potential product defects. Upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction from excessive use are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your instrument performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Electrophoresis
Analyzers > Electrophoresis Analyzers
Analyzers