Home > Services > Manuals
Sort By:
Page of 1
Buchi R-210 Rotavapor System Agilent 1200 HPLC G1315C DAD Detector Agilent 1100 HPLC G1315B DAD Detector
Buchi R-210 Rotavapor System
Our Price: $7,305.00
Deal of the Month Price: $6,495.00
Money Saved: $810.00
6 in stock!
Agilent 1200 HPLC G1315C DAD Detector
Our Price: $7,695.00
1 in stock!
Agilent 1100 HPLC G1315B DAD Detector
Our Price: $6,955.00
Sale Price: $4,495.00
Money Saved: $2,460.00
1 in stock!

Buchi R-210 Rotavapor System Specifications

Capacity Range

50ml ‚ 4L

Condenser Type

Two-piece cold trap Condenser

Pump Model

V-700 Vacuum Pump

Bath Model

B-491 Heating Bath

Vacuum Controller Model

V-850 Vacuum Controller

Rotation Speed

20 -280 rpm

Temperature Range

+20°C to +180°C

Electrical Requirements

100-120V, 50/60Hz, 60W

Agilent 1200 HPLC G1315C Diode Array Detector Specifications

Type

Specification

Detection type

1024-element photodiode array

Light Source

Deuterium and tungsten lamps

Wavelength range

190 ‚ 950 nm

Short term noise (ASTM) single and multi-Wavelength

± 1 ƒ” 10-5 AU at 254 and 750 nm

Drift

2 ƒ” 10-3 AU/hr at 254 nm

Linear absorbance

range

> 2 AU (upper limit)

Wavelength Accuracy

± 1 nm

Wavelength bunching

1 ‚ 400 nm

Slit width

1, 2, 4, 8, 16 nm

Diode Width

< 1 nm

Flow Cells

Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum

Control and data evaluation

Agilent ChemStation for LC

Analog outputs

Recorder/integrator: 100 mV or 1 V, output range 0.001 ‚ 2 AU, two outputs

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional

Safety and maintainence

Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas

GLP features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

Housing

All materials recyclable

Agilent 1100 HPLC G1315B Diode Array Detector Specifications

Type

Specification

Detection type

1024-element photodiode array

Light Source

Deuterium and tungsten lamps

Wavelength range

190 ‚ 950 nm

Short term noise (ASTM) single and multi-Wavelength

± 1 ƒ” 10-5 AU at 254 and 750 nm

Drift

2 ƒ” 10-3 AU/hr at 254 nm

Linear absorbance

range

> 2 AU (upper limit)

Wavelength Accuracy

± 1 nm

Wavelength bunching

1 ‚ 400 nm

Slit width

1, 2, 4, 8, 16 nm

Diode Width

< 1 nm

Flow Cells

Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum

Control and data evaluation

Agilent ChemStation for LC

Analog outputs

Recorder/integrator: 100 mV or 1 V, output range 0.001 ‚ 2 AU, two outputs

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional

Safety and maintainence

Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas

GLP features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

Housing

All materials recyclable

Buchi R-210 Rotavapor System with Chiller Buchi R-210 Rotavapor System (No Pump) Buchi R-215 Rotavapor System with Chiller
Buchi R-210 Rotavapor System with Chiller
Our Price: $8,595.00
2 in stock!
Buchi R-210 Rotavapor System (No Pump)
Our Price: $5,835.00
Sale Price: $4,595.00
Money Saved: $1,240.00
2 in stock!
Buchi R-215 Rotavapor System w/ Chiller
Our Price: $9,395.00
1 in stock!

Buchi R-210 Rotavapor System Specifications with Chiller

Capacity Range

50ml ‚ 4L

Condenser Type

Coil Condenser

Pump Model

V-700 Vacuum Pump

Bath Model

B-491 Heating Bath

Vacuum Controller Model

V-850 Vacuum Controller

Rotation Speed

20 -280 rpm

Temperature Range

+20°C to +180°C

Electrical Requirements

100-120V, 50/60Hz, 60W

Buchi R-210 Rotavapor System Specifications

Capacity Range

50ml ‚ 4L

Condenser Type

Dry Ice Condenser

Bath Model

B-491 Heating Bath

Vacuum Controller Model

V-850 Vacuum Controller

Rotation Speed

20 -280 rpm

Temperature Range

+20°C to +180°C

Electrical Requirements

100-120V, 50/60Hz, 60W

Buchi R-215 Rotavapor System Specifications with Chiller

Capacity Range

50ml ‚ 4L

Condenser Type

Coil Condenser

Pump Model

V-700 Vacuum Pump

Bath Model

B-491 Heating Bath

Vacuum Controller Model

V-855 Vacuum Controller

Rotation Speed

20 -280 rpm

Temperature Range

-20°C to +170°C

Electrical Requirements

100-120V, 50/60Hz, 60W